Estimation of size-specific dose estimates (SSDE) for paediatric and adults patients based on a single slice

Physica Medica, 2020
Volume averaged CT dose index (CTDIvol) is an important dose index utilized for CT dosimetry. Measurements of CTDIvol are performed in reference cylindrical phantoms of specified diameters. A size-specific dose estimate (SSDE) has been recommended for assessment of doses delivered to individual patients.
Abdullah Abuhaimed, Colin J Martin
openaire   +2 more sources

Size-Specific Dose Estimates for Evaluation of Individual Patient Dose in CT Protocol for Renal Colic

American Journal of Roentgenology, 2015
The purpose of this study is to retrospectively evaluate size-specific dose estimates of a renal-colic CT protocol and to assess the quality and diagnostic value of obtained images.The study population included 82 consecutive adult patients with acute renal colic undergoing CT with a reduced radiation dose (noise index, 59.1).
Łukasz A, Waszczuk   +3 more
openaire   +2 more sources

PATIENT DOSE SURVEY BASED ON SIZE-SPECIFIC DOSE ESTIMATE AND ACCEPTABLE QUALITY DOSE IN CHEST AND ABDOMEN/PELVIS CT EXAMINATIONS.

Radiation Protection Dosimetry, 2019
The practical aspects of two recently developed patient dose optimization methods in computed tomography (CT) examinations, size-specific dose estimate (SSDE) and acceptable quality dose (AQD), were verified for the chest and abdomen/pelvis examinations.
A. Mehdipour, Masoumeh Parsi, F. Khorram
semanticscholar   +1 more source

Size-specific dose estimates (SSDEs) for computed tomography and influencing factors on it: a systematic review

Journal of Radiological Protection, 2021
Abstract The actual dose received during a computed tomography (CT) examination depends on both the patient size and the radiation output of the scanner. To represent the actual patient morphometry, a new radiation dose metric named size-specific dose estimates (SSDEs) was developed by the American Association of Physicists in ...
D M Satharasinghe   +3 more
openaire   +2 more sources

Size specific dose estimates in pediatric chest, abdomen and pelvis CT examinations

Physica Medica, 2016
Introduction Volume computed tomography dose index (CTDIvol) does not contain any dose information regarding the patient size. Size specific dose estimates (SSDE) give more reliable results accounting for the patient size as well. This parameter uses CTDIvol and size dependent conversion factors (fDw) which are calculated by means of water equivalent ...
Akgüngör, Kadir   +2 more
openaire   +3 more sources

Influence of cone beam CT (CBCT) scan parameters on size specific dose estimate (SSDE): a Monte Carlo study

Physics in Medicine and Biology, 2019
The CT dose index (CTDIvol) is the dosimetric quantity used for multi-slice CT (MSCT) with beams  ⩽4 cm. Conversion factors (f size) based on patient size are applied to CTDIvol to adjust for differences in patient size and derive size-specific dose ...
A. Abuhaimed, C. Martin, O. Demirkaya
semanticscholar   +1 more source

Evaluation of Size Correction Factor for Size-specific Dose Estimates (SSDE) Calculation

Japanese Journal of Radiological Technology, 2016
American Association of Physicists in Medicine (AAPM) Report No.204 recommends the size-specific dose estimates (SSDE), wherein SSDE=computed tomography dose index-volume (CTDIvol )×size correction factor (SCF), as an index of the CT dose to consider patient thickness.
Kazufusa, Mizonobe   +6 more
openaire   +2 more sources

Evaluation of Size-Specific Dose Estimates in Pediatric Abdominal CT

Korean Society of Computed Tomographic Technology
In pediatric abdominal CT examinations, the conventional CT dose index (CTDIvol) has limitations as it does not account for the patient’s body size. To address this issue, the American Association of Physicists in Medicine (AAPM) introduced the concept of size-specific dose estimate (SSDE), which considers individual patient body size.
Yoon-Chul Nam   +3 more
openaire   +1 more source

Radiation dose in chest CT: Assessment of size-specific dose estimates based on water-equivalent correction

Physica Medica, 2016
In the setting of thorax Computed Tomography (CT), the main purpose of this work is to quantify differences in Size-Specific Dose Estimate (SSDE), calculated on the basis of both effective diameter and water-equivalent diameter, accounting for patient size and tissue attenuation, respectively.An in-house software was developed to measure water ...
M, Gabusi   +4 more
openaire   +2 more sources

Introduction and evaluation of size-specific DLP for radiation dose estimation in CT examinations

Journal of Radiological Protection
Abstract The increased utilization of computed tomography (CT) has raised concerns about patient radiation exposure. Effective dose (ED), which requires precise estimation, is crucial for assessing and managing these risks. Traditional ED estimation methods, which are based on the dose-length product (DLP), often lack accuracy due to ...
Yutaka Dendo   +5 more
openaire   +2 more sources