Physica Medica, 2020
Volume averaged CT dose index (CTDIvol) is an important dose index utilized for CT dosimetry. Measurements of CTDIvol are performed in reference cylindrical phantoms of specified diameters. A size-specific dose estimate (SSDE) has been recommended for assessment of doses delivered to individual patients.
Abdullah Abuhaimed, Colin J Martin
openaire +2 more sources
Volume averaged CT dose index (CTDIvol) is an important dose index utilized for CT dosimetry. Measurements of CTDIvol are performed in reference cylindrical phantoms of specified diameters. A size-specific dose estimate (SSDE) has been recommended for assessment of doses delivered to individual patients.
Abdullah Abuhaimed, Colin J Martin
openaire +2 more sources
American Journal of Roentgenology, 2015
The purpose of this study is to retrospectively evaluate size-specific dose estimates of a renal-colic CT protocol and to assess the quality and diagnostic value of obtained images.The study population included 82 consecutive adult patients with acute renal colic undergoing CT with a reduced radiation dose (noise index, 59.1).
Łukasz A, Waszczuk +3 more
openaire +2 more sources
The purpose of this study is to retrospectively evaluate size-specific dose estimates of a renal-colic CT protocol and to assess the quality and diagnostic value of obtained images.The study population included 82 consecutive adult patients with acute renal colic undergoing CT with a reduced radiation dose (noise index, 59.1).
Łukasz A, Waszczuk +3 more
openaire +2 more sources
Radiation Protection Dosimetry, 2019
The practical aspects of two recently developed patient dose optimization methods in computed tomography (CT) examinations, size-specific dose estimate (SSDE) and acceptable quality dose (AQD), were verified for the chest and abdomen/pelvis examinations.
A. Mehdipour, Masoumeh Parsi, F. Khorram
semanticscholar +1 more source
The practical aspects of two recently developed patient dose optimization methods in computed tomography (CT) examinations, size-specific dose estimate (SSDE) and acceptable quality dose (AQD), were verified for the chest and abdomen/pelvis examinations.
A. Mehdipour, Masoumeh Parsi, F. Khorram
semanticscholar +1 more source
Journal of Radiological Protection, 2021
Abstract The actual dose received during a computed tomography (CT) examination depends on both the patient size and the radiation output of the scanner. To represent the actual patient morphometry, a new radiation dose metric named size-specific dose estimates (SSDEs) was developed by the American Association of Physicists in ...
D M Satharasinghe +3 more
openaire +2 more sources
Abstract The actual dose received during a computed tomography (CT) examination depends on both the patient size and the radiation output of the scanner. To represent the actual patient morphometry, a new radiation dose metric named size-specific dose estimates (SSDEs) was developed by the American Association of Physicists in ...
D M Satharasinghe +3 more
openaire +2 more sources
Size specific dose estimates in pediatric chest, abdomen and pelvis CT examinations
Physica Medica, 2016Introduction Volume computed tomography dose index (CTDIvol) does not contain any dose information regarding the patient size. Size specific dose estimates (SSDE) give more reliable results accounting for the patient size as well. This parameter uses CTDIvol and size dependent conversion factors (fDw) which are calculated by means of water equivalent ...
Akgüngör, Kadir +2 more
openaire +3 more sources
Physics in Medicine and Biology, 2019
The CT dose index (CTDIvol) is the dosimetric quantity used for multi-slice CT (MSCT) with beams ⩽4 cm. Conversion factors (f size) based on patient size are applied to CTDIvol to adjust for differences in patient size and derive size-specific dose ...
A. Abuhaimed, C. Martin, O. Demirkaya
semanticscholar +1 more source
The CT dose index (CTDIvol) is the dosimetric quantity used for multi-slice CT (MSCT) with beams ⩽4 cm. Conversion factors (f size) based on patient size are applied to CTDIvol to adjust for differences in patient size and derive size-specific dose ...
A. Abuhaimed, C. Martin, O. Demirkaya
semanticscholar +1 more source
Evaluation of Size Correction Factor for Size-specific Dose Estimates (SSDE) Calculation
Japanese Journal of Radiological Technology, 2016American Association of Physicists in Medicine (AAPM) Report No.204 recommends the size-specific dose estimates (SSDE), wherein SSDE=computed tomography dose index-volume (CTDIvol )×size correction factor (SCF), as an index of the CT dose to consider patient thickness.
Kazufusa, Mizonobe +6 more
openaire +2 more sources
Evaluation of Size-Specific Dose Estimates in Pediatric Abdominal CT
Korean Society of Computed Tomographic TechnologyIn pediatric abdominal CT examinations, the conventional CT dose index (CTDIvol) has limitations as it does not account for the patient’s body size. To address this issue, the American Association of Physicists in Medicine (AAPM) introduced the concept of size-specific dose estimate (SSDE), which considers individual patient body size.
Yoon-Chul Nam +3 more
openaire +1 more source
Physica Medica, 2016
In the setting of thorax Computed Tomography (CT), the main purpose of this work is to quantify differences in Size-Specific Dose Estimate (SSDE), calculated on the basis of both effective diameter and water-equivalent diameter, accounting for patient size and tissue attenuation, respectively.An in-house software was developed to measure water ...
M, Gabusi +4 more
openaire +2 more sources
In the setting of thorax Computed Tomography (CT), the main purpose of this work is to quantify differences in Size-Specific Dose Estimate (SSDE), calculated on the basis of both effective diameter and water-equivalent diameter, accounting for patient size and tissue attenuation, respectively.An in-house software was developed to measure water ...
M, Gabusi +4 more
openaire +2 more sources
Introduction and evaluation of size-specific DLP for radiation dose estimation in CT examinations
Journal of Radiological ProtectionAbstract The increased utilization of computed tomography (CT) has raised concerns about patient radiation exposure. Effective dose (ED), which requires precise estimation, is crucial for assessing and managing these risks. Traditional ED estimation methods, which are based on the dose-length product (DLP), often lack accuracy due to ...
Yutaka Dendo +5 more
openaire +2 more sources