Results 201 to 210 of about 13,693,867 (238)
Some of the next articles are maybe not open access.
Evaluation of Size Correction Factor for Size-specific Dose Estimates (SSDE) Calculation
Japanese Journal of Radiological Technology, 2016American Association of Physicists in Medicine (AAPM) Report No.204 recommends the size-specific dose estimates (SSDE), wherein SSDE=computed tomography dose index-volume (CTDIvol )×size correction factor (SCF), as an index of the CT dose to consider patient thickness.
Kazufusa, Mizonobe +6 more
openaire +2 more sources
THE SIZE-SPECIFIC DOSE ESTIMATE (SSDE) FOR TRUNCATED COMPUTED TOMOGRAPHY IMAGES
Radiation Protection Dosimetry, 2016The purpose of this study is to investigate truncated axial computed tomography (CT) images in the clinical environment and to produce correction factors for abdomen, thoracic and head regions based on clinical data, in order to accurately predict the water-equivalent diameter (DW) and size-specific dose estimate (SSDE). We investigated axial images of
Choirul, Anam +4 more
openaire +2 more sources
SIZE-SPECIFIC DOSE ESTIMATES IN PEDIATRIC BRAIN CT IN RELATION TO AGE AND WEIGHT
Radiation Protection Dosimetry, 2023Abstract The size-specific dose estimate (SSDE) is used for radiation dose management in computed tomography (CT) and represents patient’s absorbed dose more accurately than volume CT dose index. The relationship between SSDE and age or weight was investigated using 980 pediatric brain CT scans.
Kaoru, Fujii +5 more
openaire +2 more sources
Size-specific dose estimates for various weighting factors of CTDI equation
Physical and Engineering Sciences in Medicine, 2019Size-specific dose estimate (SSDE) was proposed by the American Association of Physicists in Medicine (AAPM) Task Group 204 to consider the effect of patient size in the x-ray CT dose estimation. Size correction factors to calculate SSDE were derived based on the conventional weighted CT dose index (CTDIw) equation.
Tomonobu Haba +2 more
openaire +2 more sources
Physical and Engineering Sciences in Medicine
The aim of this study was to evaluate the point doses using a distribution of the size-specific dose estimate (SSDE) from axial CT images of in-house phantoms having diameters from 8 to 40 cm. In-house phantoms made of polyester-resin (PESR) mixed with methyl ethyl ketone peroxide (MEKP) were used.
Choirul Anam +6 more
openaire +2 more sources
The aim of this study was to evaluate the point doses using a distribution of the size-specific dose estimate (SSDE) from axial CT images of in-house phantoms having diameters from 8 to 40 cm. In-house phantoms made of polyester-resin (PESR) mixed with methyl ethyl ketone peroxide (MEKP) were used.
Choirul Anam +6 more
openaire +2 more sources
Automated size-specific dose estimates using deep learning image processing
Medical Image Analysis, 2021An automated vendor-independent system for dose monitoring in computed tomography (CT) medical examinations involving ionizing radiation is presented in this paper. The system provides precise size-specific dose estimates (SSDE) following the American Association of Physicists in Medicine regulations. Our dose management can operate on incomplete DICOM
Jan Maria Juszczyk +10 more
openaire +4 more sources
Physica Medica, 2020
Volume averaged CT dose index (CTDIvol) is an important dose index utilized for CT dosimetry. Measurements of CTDIvol are performed in reference cylindrical phantoms of specified diameters. A size-specific dose estimate (SSDE) has been recommended for assessment of doses delivered to individual patients.
Abdullah Abuhaimed, Colin J Martin
openaire +2 more sources
Volume averaged CT dose index (CTDIvol) is an important dose index utilized for CT dosimetry. Measurements of CTDIvol are performed in reference cylindrical phantoms of specified diameters. A size-specific dose estimate (SSDE) has been recommended for assessment of doses delivered to individual patients.
Abdullah Abuhaimed, Colin J Martin
openaire +2 more sources
Size Specific Dose Estimates and Effective Dose in Multiphase Abdomen-Pelvis CT Examinations
Radiation Physics and ChemistryPhilomina Akhilesh +2 more
exaly +2 more sources
Size specific dose estimates in pediatric chest, abdomen and pelvis CT examinations
Physica Medica, 2016Introduction Volume computed tomography dose index (CTDIvol) does not contain any dose information regarding the patient size. Size specific dose estimates (SSDE) give more reliable results accounting for the patient size as well. This parameter uses CTDIvol and size dependent conversion factors (fDw) which are calculated by means of water equivalent ...
Akgüngör, Kadir +2 more
openaire +3 more sources
Evaluation of Size-Specific Dose Estimates in Pediatric Abdominal CT
Korean Society of Computed Tomographic TechnologyIn pediatric abdominal CT examinations, the conventional CT dose index (CTDIvol) has limitations as it does not account for the patient’s body size. To address this issue, the American Association of Physicists in Medicine (AAPM) introduced the concept of size-specific dose estimate (SSDE), which considers individual patient body size.
Yoon-Chul Nam +3 more
openaire +1 more source