Results 11 to 20 of about 14,477 (264)
With its connection to distribution networks, the inverter-interfaced distributed generators (IIDGs) affect single-phase grounding detection and jeopardize their safe and stable operation. Based on the characteristics of IIDGs and sequence network theory,
JIANG Miao +3 more
doaj +1 more source
It is important to select the fault line rapidly when single-phase grounding fault occurs in the small current grounding system. The fault information acquisition of existing methods generally need hardware modification, so the high cost makes it ...
Junyang Tian +4 more
doaj +1 more source
Research and Analysis of Small Current Grounding Line Selection System
Abstract In the small current grounding system, because the short-circuit fault of single-phase grounding accounts for more than 80% of the total short-circuit fault, the selection of single-phase grounding fault line is still the main problem in electrical engineering.
Jiang Xinzheng, Jiang Nan
openaire +1 more source
Faulty Section Location Method Based on Dynamic Time Warping Distance in a Resonant Grounding System
When a single-phase grounding fault occurs in a resonant grounding system, the determination of the fault location remains a significant challenge due to the small fault current and the instability of the grounding arc.
Yu He +6 more
doaj +1 more source
Application Study of Distributed Grounding Line Selection Method Based on GOOSE Communication
A GOOSE communication-based distributed grounding line selection method is introduced and implemented in the relay protection device. When a single-phase grounding fault happens in the small current grounding system, the fault current is quite small due ...
Hongshan CHEN +4 more
doaj +1 more source
Simulation and analysis of single-phase grounding fault in small current grounding system
Abstract The characteristics and distribution of single-phase grounding faults in small current grounding system are not easy to capture, and it is not easy to collect and cover all possible situations in operation site. This paper builds a fault simulation model of distribution network based on PSCAD.
Jinwei Fu +3 more
openaire +1 more source
Research of Single-phase Grounding Fault Simulation for Small Current Grounding System
Our country generally uses small current grounding system (the neutral point no direct grounding system). Due to the fault current is too small to identify. So the distribution network operators have been plagued by this kind of fault line selection accuracy. This research establishes simulink model to analyze the fault of single-phase grounding system
Wei-wei GE +4 more
openaire +2 more sources
AN OPINION: WHAT AN ECOLOGICAL SYSTEM IS IT? [PDF]
Many controversial debates (including conferences, symposia and of of the same) are generated by misunderstanding of the concepts or, often, by associating wrong terms to the same concept.
DINGA Emil
doaj +1 more source
Fault Location for Active Distribution Network Based on Improved LMD and Energy Relative Entropy
In view of the characteristics of distribution network with large-scale integration of distributed generation when single-phase grounding fault occurs, such as complex structure and operation mode, obscure electrical quantity after fault, weak fault ...
Yanchun XU +3 more
doaj +1 more source
A Review of Fault Location Methods for Small Current Grounding Systems
Abstract Small current grounding system is mainly used in China’s distribution network. When single-phase grounding fault occurs in the distribution network, it is important to quickly and accurately select the fault line and locate the fault section to ensure the safe and stable operation of the system. In this paper, the fault location
Jiapei Li +5 more
openaire +1 more source