Results 151 to 160 of about 31,854 (268)
Breathing irregularities and postnatal hypoxaemia in an experimental model of essential hypertension
Abstract figure legend Neonatal spontaneously hypertensive rats (SHRs) exhibit inherent respiratory dysfunction in early life, including oscillatory breathing patterns and apnoeic events that cause oxygen desaturation and brain hypoxia, in addition to an impaired hypoxic ventilatory response.
Beatriz N. Vieira +7 more
wiley +1 more source
Reliability and Life Research of Certain Autonomous Emergency Solenoid Valve
[Objective] To achieve the autonomous control and safe application of emergency solenoid valves, a reliability and accelerated life test research on autonomous emergency solenoid valves is carried out. The existing design is improved through test results
DU Zhanjiang, TAO Fuwen
doaj +1 more source
Distribusi Medan Magnet Pada Solenoid [PDF]
The magnetic field is a field that is formed by moving electrical charges (electric current) which cause emergence of force in an electric charge that moves. Near all object that characteristic of metal can be pulled by a magnet.
Dwi Sudharma, Kukuh +5 more
core
Abstract figure legend The study investigated the modulatory effects of affective touch on temporal summation of second pain (TSSP) in 32 romantic couples (N = 64). The design included a dyadic session (partner's CT‐optimal stroking vs. static touch) and an individual session (robotic CT‐touch vs. vibration control).
Márcia da‐Silva +5 more
wiley +1 more source
ABSTRACT Rationale Quantum cascade laser absorption spectroscopy (QCLAS) is a fast and reliable method for analyzing the bulk (𝛿13C‐CH4, 𝛿D‐CH4) and clumped isotopic (∆13CH3D and ∆12CH2D2) composition of methane. However, precise measurements of ∆12CH2D2 require 0.5 to 1.8 mmol of purified methane (equivalent to 15 to 40 mL at STP).
Nico Kueter +6 more
wiley +1 more source
Given a sequence of regular finite coverings of complete Riemannian manifolds, we consider the covering solenoid associated with the sequence. We study the leaf-wise Laplacian on the covering solenoid. The main result is that the spectrum of the Laplacian on the covering solenoid equals the closure of the union of the spectra of the manifolds in the ...
openaire +2 more sources
Time‐Conditioned Zero‐Shot Self‐Supervised Reconstruction for Accelerated 3D Ultra‐Low‐Field MRI
ABSTRACT Purpose Ultra‐low‐field (ULF) MRI provides a cost‐effective, portable imaging option but has relatively low SNR and long acquisition times compared to standard clinical scans. This study presents a time‐conditioned zero‐shot self‐supervised learning image reconstruction framework (ULF‐ZS‐SSL) to accelerate 3D‐acquired single‐coil ULF MRI ...
Mart W. J. van Straten +6 more
wiley +1 more source
A new stopped‐flow instrument allows kinetic measurements of reactions 10 milliseconds after initiating them by mixing in a flow cell inserted into a standard NMR probe and spectrometer. High‐speed video, pressure and NMR line‐shape data are used to characterise mixing and stopping, and a protodeboronation reaction with a 5‐millisecond half‐life used ...
Andrew M. R. Hall +6 more
wiley +1 more source
Dual-latching solenoid-actuated valve assembly [PDF]
A tube-type shutoff valve is electrically positioned to its open or closed position by a concentric electromagnetic solenoid. The valve is dual latching in that the armature of the solenoid maintains the sliding tube of the valve in an open or closed ...
Brudnicki, Myron J., Yang, Jeff
core +1 more source
A System for Retrofitting Conventional MRI Systems for Simultaneous Multinuclear MRI/MRS
We present a low‐cost system for retrofitting conventional narrow‐band MRI spectrometers with simultaneous multinuclear capability using heterodyne frequency translation. The system supports up to four nuclei and 16 receive channels, with reconfigurable transmit modes and inherent phase stability through a shared local oscillator architecture ...
Jue Hou +4 more
wiley +1 more source

