Results 61 to 70 of about 440 (156)
Four-level SVPWM Strategy of Dual Three-phase Open-winding PMSM Drive
To achieve high power rating and low current harmonics of motor drive, this paper develops a dual three-phase open-winding permanent magnet synchronous motor (DTP-OW-PMSM) drive with the DC-link voltage ratio of 2:1:1.
Haowen Jiang +5 more
doaj +1 more source
In this paper, we proposed an open circuit fault diagnosis method based on mixed logical dynamical model. The experiment verified the effectiveness and feasibility of the fault diagnosis algorithm and reduced fault diagnosis time without increasing algorithm complexity. Abstract The T‐type three‐level rectifier has garnered significant attention due to
Jianyuan Wang +4 more
wiley +1 more source
The study introduces an improved active disturbance rejection control (ADRC) method for a 12S/19P YASA‐AFFSSPM motor, utilising a new interpolation‐based function and linear error feedback to simplify tuning and enhance performance. A hybrid sensorless system combining high‐frequency injection and a sliding mode observer provides precise rotor position
Javad Rahmani‐Fard +2 more
wiley +1 more source
Fault‐Tolerant Scheme for Single‐Switch Open‐Circuit Fault in CSI‐Fed Five‐Phase PMSM
This paper investigates the single‐switch open‐circuit fault and develops a fault‐tolerant control method that reduces torque ripple and winding copper losses. ABSTRACT Due to their inherent capability to provide short‐circuit fault protection, combined with features, such as high torque density and reduced torque ripple, five‐phase permanent magnet ...
Chao Chen +4 more
wiley +1 more source
ABSTRACT Investigation of power converters for use in industrial drive applications finds that these converters are used low reliable components. To overcome this issue, in this paper, advanced power converters (multi‐pulse AC–DC and multilevel DC–AC converter) are developed and implemented to feed vector‐controlled induction motor drive (VCIMD), which
Bhim Singh, Rohit Kumar
wiley +1 more source
The discrete tonal bands generated by an electric machine stator current spectrum for the fixed Space Vector Pulse Width Modulation (SVPWM) control have side effects on the acoustic noise and vibration.
Bouyahi Henda, Adel Khedher
doaj +1 more source
A five‐level nested neutral point‐clamped inverter topology
A five‐level nested neutral point‐clamped inverter with reduced blocking‐voltage rating is presented. In each of the inverter‐leg, only one, out the eight power switches, has voltage stress of half of the input voltage. The rest of the switches have voltage stress of one‐quarter of the input voltage.
Desmond O. Obe +3 more
wiley +1 more source
Simplified double switching SVPWM implementation for three-level VSI
A generalised space vector pulse width modulation (SVPWM) framework for the realisation of all double switching states with a memory-optimised method is proposed to reduce the total harmonic distortion (THD) and to provide neutral point voltage balancing
Gopinathan Vivek +3 more
doaj +1 more source
M3D‐DPWM strategy for three‐phase four‐leg inverter with higher harmonic suppression capability
Three‐phase four‐leg inverters are widely used in power systems due to their inherent ability to handle unbalanced loads. However, with conventional 3D space vector pulse width modulation (3D‐SVPWM), high harmonics of large amplitude exist in the output ...
Ning Li +4 more
doaj +1 more source
This paper proposes a novel virtual vector space vector pulse width modulation (SVPWM) method called Average Zero common mode voltage (AZCMV) PWM to mitigate low-frequency CMV in four-level neutral point clamped (4L-NPC) inverters.
Le Nam Pham +3 more
doaj +1 more source