Results 211 to 220 of about 18,361 (259)
Some of the next articles are maybe not open access.
Determination of chromium in feces by atomic absorption spectrophotometry
Clinica Chimica Acta, 1974Abstract A new method for the determination of chromium (Cr) which is used as a continuous fecal marker for metabolic balance studies is presented. Specimens are processed in triplicate, treated with 2% ammonium chloride, and the concentration of Cr is read off in an atomic absorption spectrophotometer (AAS). The method yields excellent results, e.g.
J, Guncaga, C, Lentner, H G, Haas
openaire +2 more sources
Determination of mercury by atomic-absorption spectrophotometry
Talanta, 1981A flameless atomic-absorption system has been developed for the determination of low concentrations of mercury in gaseous, solid and liquid samples of organic and inorganic materials.
openaire +2 more sources
Determination of metals in phospholipids by atomic-absorption spectrophotometry
Talanta, 1969A procedure is described for the determination of sodium, potassium, calcium, magnesium and manganese in phospholipids by atomic-absorption spectrophotometry. The method uses a solution of phospholipid in isopentyl acetate; phosphate interference is controlled by the addition of aqueous lanthanum chloride solution homogenized with ethanol.
B, Montford, S C, Cribbs
openaire +2 more sources
Atomic absorption spectrophotometry in quantitative histochemistry
The Histochemical Journal, 1977Histochemists have acknowledged the need for quantitation in their discipline, and a majority of them report their histochemical findings with some quantitative information (Anderson & Glenner, 1973; Rosenquist, 1976). It seems to be the consensus of the histochemistry fraternity that 'direct' histochemical quantitation is the most satisfactory method,
openaire +2 more sources
Determination of serum copper with atomic absorption spectrophotometry
Clinica Chimica Acta, 1969Abstract Composition of a copper standard solution for atomic absorption spectrophotometry was devised. Addition of ethylene glycol and histidine hydrochloride to the standard solution is effective to obtain accurate results in a simple dilution of serum. Viscosity and conditions of ionization of the sample are discussed.
T, Ichida, M, Nobuoka
openaire +2 more sources
Determination of copper in foods by atomic absorption spectrophotometry
Journal of the Science of Food and Agriculture, 1970AbstractA method for determining copper in a wide range of foods by atomic absorption spectrophotometry is described and shown to be reliable and sensitive. It is shown that, when copper is chelated and extracted into ketone, very high sensitivity may be achieved; copper in aqueous extracts can be determined at a level of 0.003 ppm. The main problem of
A G, Cameron, D R, Hackett
openaire +2 more sources
Indirect determination of iodate by atomic-absorption spectrophotometry
Talanta, 1989An indirect method for determination of trace iodate in certain high-purity chemicals by atomic-absorption spectrophotometry (AAS) is described. Iodate forms a stable ion-association complex [Hg(dipy)(2)](IO(3))(2) in neutral medium, which can be extracted into methyl isobutyl ketone with 99% efficiency.
D, Chakraborty, A K, Das
openaire +2 more sources
Determination of vanadium and molybdenum by atomic-absorption spectrophotometry
Talanta, 1973A method is described for the determination by atomic-absorption spectrophotometry of vanadium and molybdenum, up to the milligram level, in samples of yellow cake, uranium-bearing minerals and geochemical standards. After attack with acids these two elements are separated from each other and from matrix elements by means of anion-exchange in 6M ...
J, Korkisch, H, Gross
openaire +2 more sources
Determination of zinc by flameless atomic absorption spectrophotometry
Analytical Biochemistry, 1973Abstract The flameless atomic absorption method described here is a simple, rapid, accurate microtechnique for determining zinc in aqueous solutions, serum, or urine. It requires no sample pretreatment, only 1.0 μl of sample per determination, no correction for viscosity differences between sample and standard solutions, and is not subject to ionic ...
D, Kurz, J, Roach, E J, Eyring
openaire +2 more sources
Application of photon-counting in atomic-absorption spectrophotometry
Talanta, 1972An analysis is given of the statistics of photon-counting as a means of making measurements in atomic-absorption spectrometry. It is concluded that the simple application of Poisson counting statistics may give an over-optimistic estimate of the error, since other sources of error, such as flame flicker and variable nebulization rate, may be more ...
R M, Dagnall, B L, Sharp, T S, West
openaire +2 more sources

