Results 231 to 240 of about 25,190 (289)
High-Sensitivity Janus Sensor Enabled by Multilayered Metastructure Based on the Photonic Spin Hall Effect and Its Potential Applications in Bio-Sensing. [PDF]
Li X, Zhang H.
europepmc +1 more source
Electric Field‐Induced Hole‐ and Electron‐Type Flat Bands in Twisted Double Bilayer Graphene
The electronic structure of twisted double bilayer graphene is visualized using angle‐resolved photoemission spectroscopy with micrometer spatial resolution at twists of 3.1∘$^\circ$ and 6.0∘$^\circ$ as a function of gate voltage. Tunable hybridization effects and flat band formation occurs between valence and conduction band states due to a finite ...
Zhihao Jiang +13 more
wiley +1 more source
Interfacial magnetic spin Hall effect in van der Waals Fe3GeTe2/MoTe2 heterostructure. [PDF]
Dai Y +15 more
europepmc +1 more source
The molecular design strategy that integrates both side chain and backbone engineering in diketopyrrolopyrrole‐based conjugated polymers to identify the optimal balance between doping efficiency and microstructural order is demonstrated. Comprehensive spectroscopic, electrochemical, morphological, and structural characterizations reveal that the ...
Taewoong Han +13 more
wiley +1 more source
Enhancing Sensitivity across Scales with Highly Sensitive Hall Effect‐Based Auxetic Tactile Sensors
Herein, a tactile sensor based on hall‐effect sensors with an auxetic structure, called Hall effect‐based auxetic tactile sensor (HEATS), is proposed. The change in magnetism resulting from the deformation of the auxetic structure is utilized for sensing.
Youngheon Yun +6 more
wiley +1 more source
Higher-order quantum spin Hall effect in a photonic crystal. [PDF]
Xie B +10 more
europepmc +1 more source
This review aims to provide a broad understanding for interdisciplinary researchers in engineering and clinical applications. It addresses the development and control of magnetic actuation systems (MASs) in clinical surgeries and their revolutionary effects in multiple clinical applications.
Yingxin Huo +3 more
wiley +1 more source
It is a fact that slippage causes tracking errors in both longitudinal and lateral directions which results to have less travel distance in tracking a reference trajectory. Less travel distance means having energy loss of the battery and carrying loads less than planned.
Gokhan Bayar +2 more
wiley +1 more source
Microrobotic Catheterization of the Ophthalmic Artery for Targeted Treatment of Retinoblastoma
A microrobotic platform is presented that allows teleoperated and autonomous navigation of flow‐driven magnetic microcatheters, MagFlow, into the ophthalmic artery for superselective intra‐arterial infusion of chemotherapy to treat retinoblastoma. Extensive benchtop validations with patient‐derived biomimetic phantoms under optical and fluoroscopic ...
Artur Banach +5 more
wiley +1 more source
Concentric Rheostat Decoupled 3D Force‐Sensing Module for Smart Table Tennis Training
A 3D‐printed sensor array intrinsically decouples normal and shear forces through a unique concentric structural design. By integrating piezoresistive, sliding area‐varying capacitive, and concentric rheostat mechanisms, the 12‐sensor module achieves high‐resolution 3D force mapping without complex algorithms.
Zhe Liu +7 more
wiley +1 more source

