Results 181 to 190 of about 96,608 (254)

Optimal Dose of Lorundrostat in Uncontrolled Hypertension: A Dose Response Meta-Analysis. [PDF]

open access: yesDose Response
Gill OA   +15 more
europepmc   +1 more source

Variance‐Empirical Mode Decomposition Method for Fault Detection in MMC‐HVDC Transmission Lines

open access: yesEnergy Science &Engineering, EarlyView.
A variance‐embedded empirical mode decomposition (VEMD) method is proposed for fast and accurate fault detection in MMC‐HVDC transmission lines. By combining variance analysis with EMD, the method reliably detects various faults without communication links and remains robust to noise and non‐fault transients.
Seyed Amir Hosseini, Behrooz Taheri
wiley   +1 more source

A Probabilistic Fractional Order Physics Informed Mamba Kolmogorov‐Arnold Network for State‐of‐Charge Estimation in Grid‐Connected Battery Energy Storage Systems

open access: yesEnergy Science &Engineering, EarlyView.
This paper introduces the probabilistic fractional‐order Mam‐KAN (PFO‐Mam‐KAN) controller, a physics‐informed gray‐box framework for real‐time battery state‐of‐charge estimation. By unifying efficient Mamba encoders with uncertainty‐aware fractional physics, it achieves superior 0.31% RMSE accuracy and robust grid‐support operation under dynamic ...
Arun Kumar Rawat   +2 more
wiley   +1 more source

Effects of Camber of S‐Series Airfoils on Aerodynamic Performance, Entropy Generation Rate, Irreversibility, and Second Law Efficiency of Horizontal Axis Wind Turbines

open access: yesEnergy Science &Engineering, EarlyView.
Due to the depletion of fossil fuels, enhancing wind turbine efficiency is crucial. Utilizing airfoils with high lift‐to‐drag ratios significantly improves power generation by optimizing aerodynamic parameters. Furthermore, entropy generation analysis serves as an effective method for design optimization by minimizing energy losses and exergy ...
Mitra Yadegari
wiley   +1 more source

Charring Behaviour of Mass Timber: A Comparison of Thin Intumescent Coatings and Plasterboard

open access: yesFire and Materials, EarlyView.
ABSTRACT This study compares the charring behaviour of mass timber under varied heating conditions when protected by either different thin intumescent coating types or fire‐rated plasterboard layers. Bench‐scale fire experiments were conducted using the Heat‐Transfer Rate Inducing System (H‐TRIS).
Stavros Spyridakis   +4 more
wiley   +1 more source

An analysis of the critical time step size for explicit dynamics using trimmed B-splines, LR-splines, and THB-splines

open access: yesComputer Methods in Applied Mechanics and Engineering
Christoph Hollweck   +4 more
openaire   +1 more source

Home - About - Disclaimer - Privacy