Spot Weight Adaptation for Moving Target in Spot Scanning Proton Therapy [PDF]
Purpose: This study describes a real-time spot weight adaptation method in spot-scanning proton therapy for moving target or moving patient, so that the resultant dose distribution closely matches the planned dose distribution. Materials and Methods: The
Paul eMorel +7 more
doaj +8 more sources
A scanning dynamic collimator for spot-scanning proton minibeam production [PDF]
In proton minibeam radiation therapy, proton minibeams are typically produced by modulating a uniform field using a multislit collimator. Multislit collimators produce minibeams of fixed length and width, and a new collimator has to be manufactured each ...
Marios Sotiropoulos, Yolanda Prezado
doaj +6 more sources
Spot Scanning Proton Therapy for Sinonasal Malignant Tumors [PDF]
Purpose: Treatment of sinonasal malignant tumors is challenging, and evidence to establish a standard treatment is limited. Our objective was to evaluate the efficacy and safety of spot scanning proton therapy (SSPT) for sinonasal malignant tumors ...
Koichiro Nakajima, MD +10 more
doaj +2 more sources
SPOT: Scanning plant IoT facility for high-throughput plant phenotyping [PDF]
Many plant phenotyping platforms have been kept out of the reach of smaller labs and institutions due to high cost and proprietary software. The Scanning Plant IoT (SPOT) Facility, located at the University of Florida, is a mobile, laboratory-based ...
Stephen Lantin +9 more
doaj +2 more sources
Linear Energy Transfer Incorporated Spot-Scanning Proton Arc Therapy Optimization: A Feasibility Study [PDF]
PurposeTo integrate dose-averaged linear energy transfer (LETd) into spot-scanning proton arc therapy (SPArc) optimization and to explore its feasibility and potential clinical benefits.MethodsAn open-source proton planning platform (OpenREGGUI) has been
Xiaoqiang Li +10 more
doaj +2 more sources
Spot-Scanning Confocal Photon Beams for Hypofractionated Brain Radiosurgery [PDF]
Introduction Stereotactic radiosurgery (SRS) has been broadly used to treat brain tumors. In this study, a dose kernel-based spot scanning (DKSC) treatment delivery has been developed for hypofractionated brain SRS.
Lijun Ma PhD +8 more
doaj +2 more sources
Clinical Viability of an Active Spot Scanning Beam Delivery System With a Newly Developed Carbon-Ion Treatment Planning System [PDF]
Purpose: Although active spot scanning irradiation technique is theoretically superior to passive-scattered broad beam irradiation with respect to normal tissue sparing, corroborations of the clinical benefit of carbon-ion spot scanning have remained ...
Yixiao Guo, MD +4 more
doaj +2 more sources
A feasibility study on a machine-learning-based quality assurance tool for spot-scanning proton therapy using delivery log files and treatment plans [PDF]
Background and purpose: Although pencil beam scanning provides superior dose conformity, delivery uncertainties remain in beam monitoring and steering systems. This study evaluates a machine learning model that predicts delivered spot positions from plan
Sang Kyun Yoo +9 more
doaj +2 more sources
Analysis of the Rate of Re-planning in Spot-Scanning Proton Therapy [PDF]
Purpose: Finite proton range affords improved dose conformality of radiation therapy when patient regions-of-interest geometries are well characterized.
Yue-Houng Hu, PhD +6 more
doaj +2 more sources
Evaluation of dosimetry quantities in passive scattering and spot scanning methods in proton therapy based on GATE simulation [PDF]
Thespot-scan based methods are expected to perform better than other methods for proton therapy in delivering the dose to the intended target. In this study, the GATE computer code is used to evaluate important dosimetric quantities in proton therapy ...
A. Asadi, S.A. Hosseini, N. Vosoughi
doaj +1 more source