Results 71 to 80 of about 14,105 (205)

Admittance‑Based Two‑Stage Optimisation of GFM‑STATCOM Parameters for Transient Voltage Support in DFIG Wind Farms

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
This paper builds an admittance model for a DFIG‐STATCOM parallel system. Based on the system, the paper provides a method to optimise the control of the STATCOM, which aims to increase the performance of the system during symmetrical faults .
Wenhao Du   +5 more
wiley   +1 more source

Performance Analysis for Control of A Unified Power Flow Controller (UPFC) Using MATLAB Simulink [PDF]

open access: yesE3S Web of Conferences
The long transmission system is required to transfer generated power to distribution system. Hence, maximum power transfer devices with flexible operation are essential in transmission system. Thus, it is necessary to add Flexible AC Transmission System (
Suresh Kumar A.   +5 more
doaj   +1 more source

A hybrid multilevel converter for medium and high voltage applications [PDF]

open access: yes, 2010
This paper investigates the suitability of the hybrid multilevel converter for medium and high voltage application. The converter operation, modulation, and capacitor voltage balancing method are described in detail.
Adam, Grain Philip   +4 more
core  

A Hybrid‐Frequency Modulation Method for Cascaded H‐Bridge STATCOM With the Hybrid‐Frequency Power Loop

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
To address DC‐side voltage imbalance in star‐connected cascaded H‐bridge STATCOMs under unbalanced grids, a hybrid‐frequency power loop is introduced to enable interphase power transfer. A hybrid‐frequency PWM (HFPWM) method based on voltage vector superposition is proposed, which maintains superior output characteristics for the intermediate‐frequency
Zhendong Ji   +4 more
wiley   +1 more source

Five Level Cascaded H-Bridge D-STATCOM using a new Fuzzy and PI Controllers model for Wind Energy Systems

open access: yesAdvances in Electrical and Computer Engineering, 2017
Power quality is one of the important issues in wind energy systems as in all renewable energy systems. Reactive component of current in distribution systems causes negative effects on the network, including power loses, voltage drop, and reduced line ...
YANMAZ, K., ALTAS, I. H., MENGI, O. O.
doaj   +1 more source

Comparison between two VSC-HVDC transmission systems technologies : modular and neutral point clamped multilevel converter [PDF]

open access: yes, 2009
The paper presents a detail comparison between two voltage source converter high voltage dc transmission systems, the first is based on neutral point-clamped (also known as HVDC-Light) and the second is based on innovative modular multilevel converter ...
Adam, G.P.   +5 more
core  

An Optimization Method for Solving Three‐Phase Unbalance and Vehicle‐to‐Grid Reactive Power Compensation Utilizing Three‐Phase Inverter Control

open access: yesIET Intelligent Transport Systems, Volume 20, Issue 1, January/December 2026.
1. Using an operating power factor control method based on the instantaneous power theory to regulate voltage. 2. Designing the three‐phase four‐wire inverter s control strategy to effectively solve the three‐phase unbalanced operation problem. 3. Quantifying the regulation ability of electric vehicles as a reactive power compensation resource in the ...
Yin Yi   +5 more
wiley   +1 more source

Review of multiport modular multilevel converters for residential applications: A control perspective

open access: yesIET Power Electronics, Volume 19, Issue 1, January/December 2026.
Here, multiport modular multilevel converter (MPMMC) topologies will be reviewed and analysed from a control standpoint. It does this through identifying feasible MPMMC topologies, developing review criteria and then reviewing the feasible topologies.
Stephan Adams   +3 more
wiley   +1 more source

HVDC Transmission with STATCOM

open access: yesIOSR Journal of Engineering, 2012
Most of the HVDC power converters with thyristor valves are assembled in a converter Bridge of Six pulse configuration. Converter transformers with one DC side winding as an ungrounded star connection and the other a delta configuration. Comparative studies of the two systems of HVDC CIGRE model without STATCOM and with STATCOM were performed. In these
openaire   +1 more source

Locating and Sizing Method of MMC‐BESSs for Improving Frequency and Voltage Stability of Sending‐End Power Systems With High Proportion of New Energy

open access: yesIET Renewable Power Generation, Volume 20, Issue 1, January/December 2026.
(1) A robust optimisation model for locating and sizing the MMC‐BESS considering the frequency and voltage stability constraints is designed. (2) The description of reactive load uncertainty is researched to maintain the robustness of the optimisation model. (3) A piecewise linear solution method is proposed for the robust optimisation method.
Ying Huang   +4 more
wiley   +1 more source

Home - About - Disclaimer - Privacy