Results 91 to 100 of about 1,809 (167)
Cardiac implantable electronic devices (CIEDs) implantation using ultrasound has substantial benefits by providing real‐time visualization of veins, needles, guidewire positions, lead placement, and heart chambers. We discuss current limitations in ultrasound‐guided implantation, addressing visualization challenges, particularly in obese patients ...
Maham Bilal +4 more
wiley +1 more source
ABSTRACT Background The existing research data cannot fully prove the advantages of single‐site Da Vinci robotic surgery (RSS) compared with single‐site laparoscopic surgery (LESS) in the treatment of gynecological diseases. Aims To evaluate the effectiveness and cost of RSS and LESS in the treatment of gynecological diseases.
Jian‐Zhao Yin, Wei‐Feng Gao
wiley +1 more source
Steep Trendelenburg Positioning in gasless vNOTES Procedures: A Retrospective Study
Abstract Objective This retrospective cohort study evaluated the non-inferiority of reduced Trendelenburg positioning (≤ 20°) compared to conventional steep angles (≥ 30°) in gasless transvaginal natural orifice transluminal endoscopic surgery (vNOTES) for benign gynecologic conditions, focusing on perioperative ...
Linfeng Li +5 more
openaire +1 more source
Cerebral Oxygenation during Laparoscopic Surgery: Jugular Bulb versus Regional Cerebral Oxygen Saturation [PDF]
PURPOSE: We hypothesized that regional cerebral oxygen saturation (rSO2) could replace jugular bulb oxygen saturation (SjvO2) in the steep Trendelenburg position under pneumoperitoneum.
최승호, 오영준, 이성진
core +1 more source
PURPOSE: This study was to evaluate the effect of intraoperative continuous infusion of dexmedetomidine on intraocular pressure (IOP) in patients undergoing robot-assisted laparoscopic radical prostatectomy (RALRP) in the steep Trendelenburg (ST ...
최영득 +4 more
core +1 more source
Objective: This study aimed to compare the effects of inhalation anesthesia and total intravenous anesthesia on intraocular pressure, as well as to evaluate associated hemodynamic changes, surgical duration, blood gas parameters, and the effects of ...
Aysun Erşen Yüngül +3 more
doaj +1 more source
Note that the ONSDs during pneumoperitoneum and the Trendelenburg position (T2 and T3) do not significantly differ between the ZEEP and PEEP groups, whereas the ONSD in the PEEP group is significantly higher than that in the ZEEP group during the supine ...
Joonho Lee (1351974) +7 more
core +1 more source
. This case study demonstrates a single-position supine approach for robotic retroperitoneal lymph node dissection (R-RPLDN) for the treatment of nonseminomatous germ cell tumors and residual masses after chemotherapy. We performed a bilateral R-RPLDN in
Lei Zhou +7 more
doaj +1 more source
Robotic-assisted laparoscopic radical prostatectomy (RARP) needs a steep Trendelenburg position and a relatively high CO2 insufflation pressure, and patients undergoing RARP are usually elderly.
Eun-Su Choi +5 more
doaj +1 more source
BackgroundThis study aimed to determine whether continuous deep neuromuscular blockade (NMB) improves the surgical conditions and facilitates robotic-assisted laparoscopic radical prostatectomy (RALRP) under low intra-abdominal pressure (IAP) to ...
Young-Chul Yoo +7 more
doaj +1 more source