Results 1 to 10 of about 301,873 (263)

A New Dual Polarity Direct AC-AC Voltage Regulator Ensuring Voltage Step-Up and Step-Down Capabilities [PDF]

open access: yesApplied Sciences, 2021
The problem of voltage sag and swell is one of the major reasons for low-quality power in the distribution system. Normally, it results from the system’s faults, including line-to-ground and line-to-line, non-linear characteristics of loads and sources ...
Naveed Ashraf   +6 more
doaj   +2 more sources

Voltage Clamping Circuits for Large Voltage Step-Down Coupled Inductor Converters [PDF]

open access: yesRenewable Energy and Sustainable Development, 2019
Water desalination processes require power converters with large voltage step-down ratios and high efficiencies.  Coupled‑inductor (tapped-inductor) circuits can achieve this where the whole inductor carries current during one switch state but only part ...
Richard Pollock
doaj   +2 more sources

Reduction of the step voltages of MV/LV substation grounding system based on shaping electric field [PDF]

open access: yesArchives of Electrical Engineering, 2021
The article presents the analysis results of the effectiveness limitation of the step voltage by forming an electric field on the ground surface. For shaping the electric field, a method consisting of screens placed around the point of the earth current ...
Roman Sikora, Przemysław Markiewicz
doaj   +1 more source

The Impact of Substation Grounding Grid Design Parameters in Non-Homogenous Soil to the Grid Safety Threshold Parameters

open access: yesIEEE Access, 2021
It is important to ensure that a grounding system is designed with a low magnitude of earth resistance, so the protection system can divert the large fault current to earth effectively.
Navinesshani Permal   +3 more
doaj   +1 more source

Power Leakage Monitoring and Warning Device for Power Grid Fault Diagnosis: Design and Field Test

open access: yesFrontiers in Energy Research, 2022
Electrical equipment insulation damage, metal shell conduction on rainy days, and wire short circuits are easy to produce leakage, which form step voltage on the ground and endangers the life and safety of nearby personnel.
Qi Yang   +3 more
doaj   +1 more source

Research on lightning transient distribution characteristics of cable-stayed bridges

open access: yes暴雨灾害, 2023
Bridges are usually located at the junction of land and water, where the surrounding area is open terrain, making them to be easily damaged by lightning strikes.
Yajing SHI   +4 more
doaj   +1 more source

Design, Modeling, and Analysis of IEEE Std 80 Earth Grid Design Refinement Methods Using ETAP

open access: yesApplied Sciences, 2023
The design of a compliant, safe, and reliable substation earth grid is not a straightforward process; in most cases, it requires some additional measures to be taken due to various constraints that differ from environment to environment, such as soil ...
Vuyani Michael Nicholas Dladla   +2 more
doaj   +1 more source

Optimal Voltage Control Method for a Step Voltage Regulator Considering the Under-Load Tap Changer in a Distribution System Interconnected with a Renewable Energy Source

open access: yesEnergies, 2023
The voltage in distribution systems is controlled by the under-load tap changer of the substation and the pole transformer of the primary feeders. Recently, as one of the main countermeasures, a step voltage regulator is being introduced to solve voltage
Hyun-ok Lee   +3 more
doaj   +1 more source

Effect of Soil Resistivity Measurement on the Safe Design of Grounding Systems

open access: yesEnergies, 2020
A prerequisite for the proper and safe designing of a grounding system is the full knowledge of the ground structure in the terrain of installation.
Vasilios P. Androvitsaneas   +3 more
doaj   +1 more source

Design considerations of asymmetric step-up/down dual-resonator charger for lithium-ion battery applications

open access: yesEnergy Reports, 2022
In Lithium-ion battery charging applications, wide step-up/down voltage gain range converters are commonly used. The resonant frequency ratio and quality factor can seriously affect the switching frequency range and voltage gain characteristics of the ...
Yubo Han   +6 more
doaj   +1 more source

Home - About - Disclaimer - Privacy