Results 1 to 10 of about 4,022 (221)

Augmented Reality in Stereotactic Neurosurgery: Current Status and Issues [PDF]

open access: yesNeurologia Medico-Chirurgica, 2023
Stereotactic neurosurgery is an established technique, but it has several limitations. In frame-based stereotaxy using a stereotactic frame, frame setting errors may decrease the accuracy of the procedure.
Makoto SATOH   +3 more
doaj   +2 more sources

Deep brain stimulation of medial forebrain bundle modulates noradrenergic activity and feedforward inhibition in rodent model of depression [PDF]

open access: yesTranslational Psychiatry
Deep Brain Stimulation (DBS) of the superolateral medial forebrain bundle has shown promising long-term anti-depressant effects in treatment-resistant depression patients, although the mechanisms are not clear.
Zhuo Duan   +3 more
doaj   +2 more sources

ARISE—The Accuracy Evaluation of a Patient-Specific 3D-Printed Biopsy System Based on MRI Data: A Cadaveric Study [PDF]

open access: yesBioengineering
Background: Brain biopsy is required for the accurate specification and further diagnosis of intracranial findings. The conventional stereotactic frames are used clinically for biopsies and offer the highest possible precision.
Robert Möbius   +6 more
doaj   +2 more sources

Risk-benefit analysis of surgical treatment strategies for cystic craniopharyngioma in children and adolescents [PDF]

open access: yesFrontiers in Oncology
ObjectiveTreatment strategies for craniopharyngiomas are still under debate particularly for the young population. We here present tumor control and functional outcome data after surgical treatment focusing on stereotactic and microsurgical procedures ...
Michael Schmutzer-Sondergeld   +7 more
doaj   +2 more sources

Use of dose-area product to assess plan quality in robotic radiosurgery [PDF]

open access: yesZeitschrift für Medizinische Physik
Purpose: In robotic stereotactic radiosurgery (SRS), optimal selection of collimators from a set of fixed cones must be determined manually by trial and error.
Markus Eichner   +9 more
doaj   +2 more sources

Technical efficacy and local recurrence after stereotactic radiofrequency ablation of 2653 liver tumors: a 15-year single-center experience with evaluation of prognostic factors

open access: yesInternational Journal of Hyperthermia, 2022
Purpose To assess the technical outcome and local tumor control of multi-probe stereotactic radiofrequency ablation (SRFA) in a large series of patients.
Peter Schullian   +8 more
doaj   +1 more source

Early experience of stereotactic biopsy of brain lesion in tertiary centre of Nepal

open access: yesNepal Journal of Neuroscience, 2021
Background  Stereotactic surgery or stereotaxy is a minimally invasive form of surgical intervention which makes use of a three-dimensional coordinate system to locate small targets inside the body and to perform on them some action such as ablation,
Binit Kumar Jha   +3 more
doaj   +1 more source

Case Report: Clinical Use of a Patient-Individual Magnetic Resonance Imaging-Based Stereotactic Navigation Device for Brain Biopsies in Three Dogs

open access: yesFrontiers in Veterinary Science, 2022
Three-dimensional (3D) printing techniques for patient-individual medicine has found its way into veterinary neurosurgery. Because of the high accuracy of 3D printed specific neurosurgical navigation devices, it seems to be a safe and reliable option to ...
Sarah Gutmann   +7 more
doaj   +1 more source

Accuracy of a magnetic resonance imaging‐based 3D printed stereotactic brain biopsy device in dogs [PDF]

open access: yes, 2020
Background: Brain biopsy of intracranial lesions is often necessary to determine specific therapy. The cost of the currently used stereotactic rigid frame and optical tracking systems for brain biopsy in dogs is often prohibitive or accuracy is not ...
Böttcher, Peter   +8 more
core   +1 more source

Radiotoxicity in robotic radiosurgery: proposing a new quality index for optimizing the treatment planning of brain metastases

open access: yesRadiation Oncology, 2017
Background As irradiated brain volume at 12 Gy (V12) is a predictor for radionecrosis, the purpose of the study was to develop a model for Cyberknife (CK) plans that is able to predict the lowest achievable V12 at a given tumor size and prescription dose
Alexandra Hellerbach   +8 more
doaj   +1 more source