Results 31 to 40 of about 2,834 (263)

Feasibility and Safety of Somato‐Cognitive Coordination Therapy for Cerebellar Ataxia Following Pediatric Brain Tumor Treatment

open access: yesPediatric Blood &Cancer, EarlyView.
ABSTRACT Background Cerebellar ataxia after pediatric brain tumor treatment can cause persistent gait, balance, and speech impairment, yet no established rehabilitation strategy exists. Somato‐cognitive coordination therapy (SCCT) is a virtual reality–guided intervention designed to promote sensorimotor integration through visually constrained reaching
Masanobu Takeuchi   +10 more
wiley   +1 more source

Evaluation of metro stray current corrosion based on finite element model

open access: yesThe Journal of Engineering, 2019
Leakage currents from DC traction power supply system of metro will reduce the lifetime of the buried pipeline. This study illustrates a real contribution in the analysis of dynamic stray current and the evaluation of the corrosion status of the buried ...
Cai Zhichao, Hao Cheng
doaj   +1 more source

Prevalence of 21 Physician‐Defined Severe Toxicities Following Childhood Acute Lymphoblastic Leukemia Treatment: Australian Retrospective Cohort Study

open access: yesPediatric Blood &Cancer, EarlyView.
ABSTRACT Background Acute lymphoblastic leukemia (ALL) is the most common pediatric cancer, with an overall survival now surpassing 90% in developed countries. However, treatments are not without adverse effects. In this study, we apply the severe toxicity‐free survival (STFS) framework to determine the prevalence of 21 physician‐defined severe ...
Lane Collier   +10 more
wiley   +1 more source

Regulated Electric Drainage and its Interference with Track Circuits

open access: yesAdvances in Electrical and Electronic Engineering, 2018
Electric drainage is a power electronic device used to protect underground metal devices (such as piping) from the corrosive effects of stray currents. Stray currents are usually caused by DC electric traction, such as trams or railways.
Vaclav Kolar   +3 more
doaj   +1 more source

Electrolysis from Stray Currents—I

open access: yesScientific American, 1912
n ...
openaire   +1 more source

Sustained Therapeutic Efficacy of Intravenous Plasminogen Concentrate in Pediatric Patients With Type 1 Plasminogen Deficiency: An Analysis of Dosing Parameters and Clinical Outcomes

open access: yesPediatric Blood &Cancer, EarlyView.
ABSTRACT Background Type 1 plasminogen deficiency (PLGD‐1) is an ultra‐rare autosomal recessive disorder caused by variants in the PLG gene and affects approximately 1.6 individuals per million. The condition is characterized by decreased plasminogen levels and impaired function, resulting in fibrin‐rich lesions on mucous membranes throughout the body.
Charles Nakar   +7 more
wiley   +1 more source

Assessment Methods for DC Stray Current Corrosion Hazards in Underground Gas Pipelines: A Review Focused on Rail Traction Systems

open access: yesEnergies
Stray currents leaking from electrified DC rail systems cause the greatest corrosion risk to underground metal gas pipelines and can lead to pipeline wall perforation in a very short time. Leakage and gas explosion, and other direct and indirect effects,
Krzysztof Żakowski   +2 more
doaj   +1 more source

Power module stray inductance extraction: Theoretical and experimental analysis

open access: yesETRI Journal, 2021
We propose a stray inductance extraction method on power modules of the few‐kilovolts/several‐hundred‐amperes class using only low voltages and low currents.
Dong Yun Jung   +9 more
doaj   +1 more source

Guidelines for Pediatric Radiotherapy Simulation: A Report From the Children's Oncology Group Radiation Oncology Discipline

open access: yesPediatric Blood &Cancer, EarlyView.
ABSTRACT Pediatric radiation therapy presents unique challenges compared to adult treatments, including those of immobilization, potential need for sedation, and the critical importance of accurate, reproducible positioning. Additionally, heightened attention to imaging doses is necessary to minimize long‐term toxicity in survivors.
Parham Alaei   +17 more
wiley   +1 more source

Stray Currents Beyond the Fundamental in the Swedish BT Railway Power System

open access: yesEnergies
Sweden has a very high and variable soil resistivity, making it difficult to ensure a consistently good connection to earth along the track. Booster Transformers (BTs) have been used to ensure that the current returns through the intended path and that ...
Tommy Hjertberg   +1 more
doaj   +1 more source