Results 31 to 40 of about 26,366,925 (292)

Stray light entrance pupil: an efficient tool for stray light characterization

open access: yes, 2020
peer reviewedStray light represents a major performance limitation for optical instruments. Analyses are done with ray-tracing software to evaluate the stray light performances of a design and, if necessary, improve it before manufacturing.
Loicq, Jerôme   +4 more
core   +1 more source

Objective measurement of forward-scattered light in the human eye: An electrophysiological approach.

open access: yesPLoS ONE, 2019
PurposePsychophysical measurements are used to examine the perception of ocular stray light, for example, with C-Quant. These measurements are subjective due to their principles.
Benjamin Solf   +3 more
doaj   +1 more source

Adaption of an array spectroradiometer for total ozone column retrieval using direct solar irradiance measurements in the UV spectral range [PDF]

open access: yesAtmospheric Measurement Techniques, 2018
A compact array spectroradiometer that enables precise and robust measurements of solar UV spectral direct irradiance is presented. We show that this instrument can retrieve total ozone column (TOC) accurately. The internal stray light, which is often
R. Zuber   +5 more
doaj   +1 more source

A Vision-Based Pose Estimation of a Non-Cooperative Target Based on a Self-Supervised Transformer Network

open access: yesAerospace, 2023
In the realm of non-cooperative space security and on-orbit service, a significant challenge is accurately determining the pose of abandoned satellites using imaging sensors.
Quan Sun   +8 more
doaj   +1 more source

Micro to macro scale simulation coupling for stray light analysis

open access: yesOptics Express, 2021
Stray light in an optical system is unwanted parasitic light that may degrade performance. It can originate from different sources and may lead to different problems in the optical system such as fogging, ghost images for imagers, or inaccurate measurements for time of flight applications. One of the root causes is the reflectivity of the sensor itself.
Axel, Crocherie   +4 more
openaire   +2 more sources

The Influence of the Stimulus Design on the Harmonic Components of the Steady-State Visual Evoked Potential

open access: yesFrontiers in Human Neuroscience, 2020
Steady-state visual evoked potentials (ssVEPs) are commonly used for functional objective diagnostics. In general, the main response at the stimulation frequency is used.
Benjamin Solf   +3 more
doaj   +1 more source

Optical system design of star sensor and stray light analysis

open access: yesJournal of the European Optical Society-Rapid Publications, 2018
Background Star sensor is one of the precise attitude determination sensors. It is an electro-optical system that takes an image from a set of stars and by comparing it with the star catalogue determines angle deviation of the satellite and modifies its ...
Mohammad Asadnezhad   +2 more
doaj   +1 more source

Calibration and evaluation of CCD spectroradiometers for ground-based and airborne measurements of spectral actinic flux densities [PDF]

open access: yesAtmospheric Measurement Techniques, 2017
The properties and performance of charge-coupled device (CCD) array spectroradiometers for the measurement of atmospheric spectral actinic flux densities (280–650 nm) and photolysis frequencies were investigated.
B. Bohn, I. Lohse, I. Lohse
doaj   +1 more source

Effect of DFPP on Ferroptosis in Peripheral Blood CD14+ Monocytes of Hyperlipidemic Patients Involving the ACSL4/LPCAT3/ALOX5 Pathway

open access: yesTherapeutic Apheresis and Dialysis, EarlyView.
ABSTRACT Introduction Hyperlipidemia is a major risk factor for atherosclerotic cardiovascular disease (ASCVD). Although statins are the cornerstone of lipid‐lowering therapy, their use may be limited in some patients by adverse effects. This study evaluated the possible impact of non‐drug treatment using double‐filtration plasmapheresis (DFPP) on CD14+
Yun Cheng   +3 more
wiley   +1 more source

The Impact of Tenapanor on Body Composition and Blood Pressure in Peritoneal Dialysis Patients: A Pilot Study

open access: yesTherapeutic Apheresis and Dialysis, EarlyView.
ABSTRACT Instruction Tenapanor potentially affects fluid volume and blood pressure. This study explored its effects on these parameters in patients undergoing peritoneal dialysis (PD). Methods We conducted a single‐arm, prospective observational study that enrolled 10 patients on PD with hyperphosphatemia who were newly initiated on tenapanor.
Shun Yoshida   +11 more
wiley   +1 more source

Home - About - Disclaimer - Privacy