Results 71 to 80 of about 28,768 (295)

Comparison between two models of magnetic hysteresis accounting for stress

open access: yes, 2004
International audienceTwo models of hysteresis including the influence of an elastic stress on the magnetic behavior of the material are analyzed. They are shown to have different properties, but comparable accuracy.
Ossart, Florence, Bernard, Yves
core   +1 more source

Stress self-sensing in Amplified Piezoelectric Actuators through a fully-coupled model of hysteresis

open access: yes, 2020
Piezoelectric actuators are among the most used devices for micro-positioning applications. Yet, their output displacement shows non-negligible hysteresis effects with respect to both the input voltage and the mechanical stress and, as a consequence, an ...
Clemente C. S.   +4 more
core   +1 more source

Oxygen‐Tunnel Indium Tin Oxide Vertical Channel Transistors with Enhanced Current Density and Reliability for Monolithic 3D Compute‐In‐Memory Systems

open access: yesAdvanced Functional Materials, EarlyView.
Oxygen‐tunnel (OT) indium tin oxide (ITO) vertical channel transistors (VCTs) enable reliable, high‐density gain‐cell memory for monolithic 3D integration. A sandwiched SiN/SiO2/SiN OT stack selectively regulates oxygen transport, suppressing parasitic electrode oxidation while stabilizing channel oxygen vacancies, thereby suppressing carrier injection
Hyeonho Gu   +17 more
wiley   +1 more source

Relaxation Processes in Vulcanized Rubber. I. Relations between Stress Relaxation, Creep, Recovery, and Hysteresis

open access: yes, 1963
An experimental study is described of stress relaxation, creep, recovery, and hysteresis in vulcanized rubbers under moderate deformations. The measurements indicate that the rate of stress relaxation is substantially independent of the amount or type of
A. N. Gent
core   +1 more source

Regulated Ion‐Diffusion Hydrogels for Subtle and Multimodal Temperature‐Strain Sensing in Wound Monitoring

open access: yesAdvanced Functional Materials, EarlyView.
A soft, dual‐channel hydrogel patch enables simultaneous detection of wound temperature and strain by integrating ion‐diffusion‐mediated thermoelectric and resistive sensing. The conformal design maintains stable performance during motion, capturing subtle inflammatory and mechanical changes for continuous wound monitoring.
Yu Fang   +7 more
wiley   +1 more source

The Nature of Occupational Unemployment Rates in the United States: Hysteresis or Structural? [PDF]

open access: yes
This paper provides new evidence on the nature of occupational differences in unemployment dynamics, which is relevant for the debate between the structural or hysteresis hypotheses.
Gil-Alana, Luis A.   +2 more
core  

Stress Magnetization Hysteresis Properties of Amorphous Ribbons.

open access: yesJournal of the Magnetics Society of Japan, 1992
Magnetization of amorphous ribbon changes due to application of tensile stress under magnetic field, and it also shows hysteresis due to tension. The change of magnetization due to tension is composed of two effects: one a reversible magnetization change and the other an irreversible magnetization change.
Saito, A., Yamamoto, K.
openaire   +2 more sources

Influence of hydraulic hysteresis on effective stress in unsaturated soils

open access: yes, 2010
In this note, results from a careful programme of experimental research are presented examining the variation of the effective stress parameter along main drying and wetting paths and in transition from drying to wetting.
S. ZARGARBASHI, N. KHALILI
core   +1 more source

Monte Carlo Simulation of Ferroelectric Behavior in PZT Films by Using a Stress Dependent DIFFOUR Hamiltonian

open access: yesIngeniería y Ciencia, 2014
In this work the polarization and hysteresis response of Lead Zirconate Titanate (PZT) ferroelectric thin films was studied in relation to the variation on temperature, stress, electric field and the content of non-ferroelectric impurities by using a ...
E Restrepo-Parra   +2 more
doaj   +1 more source

Multimodal Soft Surgical Robots Enabled by Eco‐Degradable, Sterilizable Polymers and Transient Electronics

open access: yesAdvanced Functional Materials, EarlyView.
A compostable PGS soft surgical robot with interchangeable modules integrates transient Mo tactile and Si thermal sensors for dual feedback. The device preserves its function after clinical‐grade sterilization, demonstrates stable actuation and cardiac tissue grasping with real‐time in vivo pulsatile monitoring, and biodegrades post‐use with soil‐safe, 
Minseong Chae   +27 more
wiley   +1 more source

Home - About - Disclaimer - Privacy