Results 151 to 160 of about 4,462,970 (170)
Some of the next articles are maybe not open access.

Bioprosthetic valve fracture for valve‐in‐valve transcatheter aortic valve implantation in patients with structural valve degeneration: Systematic review with meta‐analysis

Journal of Cardiac Surgery, 2021
To determine the outcomes of bioprosthetic valve fracture (BVF) in valve-in-valve transcatheter aortic valve implantation (ViV-TAVI) for patients with structural valve degeneration (SVD) of bioprosthetic surgical valves (BSV) implanted during surgical aortic valve replacement (SAVR).A systematic review was conducted including studies published by May ...
Michel Pompeu Sá   +10 more
openaire   +3 more sources

A Rapid Structural Degeneration of a Porcine Mitral Valve

The Annals of Thoracic Surgery, 2012
A 73-year-old woman underwent both mitral and aortic valve replacements with porcine heart valve prostheses because of severe mitral regurgitation and severe aortic regurgitation. Ten months after surgery, maximal flow velocity of the aortic valve reached 4.6 m/sec and moderate mitral regurgitation was detected.
Takashi, Miura   +5 more
openaire   +2 more sources

Biomarkers of aortic bioprosthetic valve structural degeneration

Current Opinion in Cardiology, 2019
Bioprosthetic valves are now used for the majority of surgical aortic valve replacements and for all transcatheter aortic valve replacements. However, bioprostheses are subject to structural valve deterioration (SVD) and have, therefore limited durability.Clinical, imaging, and circulating biomarkers may help to predict or indicate the presence of ...
Erwan, Salaun   +3 more
openaire   +2 more sources

Unusual Structural Valve Degeneration in a Cloth-Covered Starr-Edwards Valve

Asian Cardiovascular and Thoracic Annals, 2006
Structural valve degeneration in a mechanical ball and cage prosthesis is a well-described entity. Here we describe an unusual case of structural valve degeneration of a cloth-covered composite-seat Starr-Edwards ball and cage valve prosthesis in the mitral position, where degeneration of the cloth covering of the seat of the valve led to significant ...
Manoj, Kuduvalli   +2 more
openaire   +2 more sources

The 10-year horizon: Survival and structural valve degeneration in first-generation transcatheter aortic valves

Archives of Cardiovascular Diseases, 2022
Transcatheter aortic valve replacement is an established treatment for high- or intermediate-risk patients with symptomatic aortic valve stenosis. As more low-risk patients are being treated, transcatheter heart valve durability is gaining importance. Data on structural valve deterioration beyond 8 years after transcatheter aortic valve replacement is ...
Magdalena, Erlebach   +8 more
openaire   +2 more sources

Multimodality evaluation of transcatheter structural valve degeneration at long-term follow-up

Revista Española de Cardiología (English Edition), 2021
We assessed the long-term hemodynamic performance of transcatheter heart valve (THV) by paired transthoracic echocardiography (TTE), and the incidence, characteristics and factors associated with THV structural valve degeneration (SVD).A total of 212 patients who underwent transcatheter aortic valve replacement and had a potential follow-up >5 years ...
Alfredo Nunes, Ferreira-Neto   +14 more
openaire   +2 more sources

Abstract 18522: Pyridoxamine (vitamin B6) Mitigation Of Structural Valve Degeneration Of Bioprosthetic Heart Valves

Circulation, 2023
Introduction: Bioprosthetic heart valves (BHV) fabricated from glutaraldehyde treated bovine pericardium (BP) have limited durability due to structural valve degeneration (SVD) resulting from both calcification and advanced glycation end product (AGE) deposition.
Andrey Zakharchenko   +5 more
openaire   +1 more source

Transapical Valve-in-Valve Implantation as a Treatment Option for Structural Degeneration of an Aortic Bioprosthesis

Revista Española de Cardiología (English Edition), 2010
Rocío Casais Pampín   +3 more
openaire   +1 more source

Home - About - Disclaimer - Privacy