Grounding System Adequacy of HV/MV Substations in Areas With Reduced Accessibility [PDF]
The adequacy of grounding systems has to be verified periodically in the operational time. With urban development and buildings growth adjacent to power systems as HV/MV substations, it is very rare to have area around with sufficient accessibility for ...
Farber, Alexander +4 more
core +1 more source
Simulation of a Power Substation's Control System Operation
This paper describes a simulator of power substation automation system developed as part of software suit for complex simulation of power substation operation.
Marek Hoger, Peter Bracinik, Marek Roch
doaj +1 more source
Electromagnetic compatibility of high voltage substation SMART devices
The article presents the results of a study of the electromagnetic compatibility of SMART devices (SD) ofautomated technological control systems (ATCS) at a high voltage electrical substation.
B. R. Kangozhin +3 more
doaj +1 more source
FPGA-based network intrusion detection for IEC 61850-based industrial network
This paper proposes an FPGA-based network intrusion detection system for the IEC 61850-based industrial network that is specially designed for substation automation. The proposed system uses the Shift-And algorithm for detecting malicious network packets
Junsik Kim, Jaehyun Park
doaj +1 more source
Data management of on-line partial discharge monitoring using wireless sensor nodes integrated with a multi-agent system [PDF]
On-line partial discharge monitoring has been the subject of significant research in previous years but little work has been carried out with regard to the management of on-site data.
M. Judd +6 more
core +2 more sources
MACsec Layer 2 Security in HSR Rings in Substation Automation Systems
The smart-grid concept takes the communications from the enclosed and protected environment of a substation to the wider city or nationwide area. In this environment, cyber security takes a key role in order to secure the communications. The challenge is
Jesús Lázaro +4 more
doaj +1 more source
Development of an integrated low-power RF partial discharge detector [PDF]
This paper presents the results from integrating a low-power partial discharge detector with a wireless sensor node designed for operating as part of an IEEE 802.15.4 sensor network, and applying an on-line classifier capable of classifying partial ...
Baker, P.C. +3 more
core +1 more source
Issues in integrating existing multi-agent systems for power engineering applications [PDF]
Multi-agent systems (MAS) have proven to be an effective platform for diagnostic and condition monitoring applications in the power industry. For example, a multi-agent system architecture, entitled condition monitoring multi-agent system (COMMAS ...
Catterson, V.M. +2 more
core +1 more source
The role of intelligent systems in delivering the smart grid [PDF]
The development of "smart" or "intelligent" energy networks has been proposed by both EPRI's IntelliGrid initiative and the European SmartGrids Technology Platform as a key step in meeting our future energy needs.
Catterson, Victoria +2 more
core +1 more source
Simplified conservative testing method of touch and step voltages by multiple auxiliary electrodes at reduced distance [PDF]
Grounding systems (GSs) must be tested periodically in order to maintain the touch voltage (TV) and step voltage (SV) below a safe value in all of the zones of the installation.
Araneo, Rodolfo +4 more
core +1 more source