Results 1 to 10 of about 214 (66)
The existing Beijing Pingguoyuan Subway Station was extended through a extension project. The excavation for the extension was located directly above the existing station.
Jianyong Han +9 more
doaj +3 more sources
A reasonable seismic capacity model is crucial for establishing the seismic performance level system and evaluating the seismic reliability of subway station structures.
Minze Xu +5 more
doaj +3 more sources
Due to the planning of the subway route, it is difficult to avoid crossing soft soil site conditions at subway stations. The seismic response of subway station structures is closely related to the surrounding soil site.
Guanyu Yan +4 more
doaj +3 more sources
Assembled monolithic subway station partly synthesizes the advantages of cast-in-place and precast subway stations. However, the related seismic response analysis considering the influences of vertical ground motion and aboveground structure is still ...
Yu Miao, Han-Wen Ji, Yang Shi
doaj +3 more sources
Seismic response of subway station structure with concrete-filled-steel-tube middle columns
In order to improve the seismic performance of underground structures, the concrete-filled steel tube (CFST) middle column is usually used in the existing subway station structures.
ZHONG Zilan , GUO Qinglong , GUO Jiaxi , ZHANG Bu , ZHAO Mi
doaj +1 more source
Incremental dynamic analysis of underground subway station structure [PDF]
Incremental dynamic analysis constitutes the basis of seismic performance evaluation and seismic vulnerability assessment. In this paper, a typical two-story three-span subway station structure is selected as an example structure and its incremental ...
Liu Tong +3 more
doaj +1 more source
The optimal index of earthquake intensity measures required in the probabilistic seismic demand model for seismic design of the underground frame structure of shallow-buried subway station is studied.
JIANG Jiawei 1, 2, XU Chengshun 3, DU Xiuli 3, CHEN Guoxing 1, 2, XU Zigang 4
doaj +1 more source
In view of the seismic weak component of the single-frame-type subway station structure, the three-dimensional (3D) time-domain nonlinear finite element static-dynamic coupling analysis model of interaction between soil and subway station structure is ...
Sheng Li +4 more
doaj +1 more source
Shaking table tests on seismic response of a subway station structure in ground fissure site
The safety of subway is seriously threatened by the coupling effects of earthquakes and ground fissures. A shaking table test is conducted on a subway station structure in a ground fissure site (structure crossing the ground fissure), and the ...
CHEN Xuan 1, 2, 3, XIONG Zhong-ming 1, 2, 3, CHEN Zhi 1, 2, 3
doaj +1 more source
Experimental study on the temperature distribution in a cross-type interchange subway station fire scenario [PDF]
In order to investigate the temperature distribution beneath the subway ceiling, a series of experiments were carried out in a 1:20 small-scale model of a three-level cross-type interchange subway station.
Li Jiaxin +3 more
doaj +1 more source

