Results 21 to 30 of about 265 (212)

Investigation of the Operation of Active Superconducting Fault Current Limiters in Distribution Networks Connected to Microgrids [PDF]

open access: yesJournal of Applied Research in Electrical Engineering, 2023
Increasing the penetration level of distributed generation (DG) units in radial power distribution systems can increase the short-circuit level in these networks, which can, in turn, have destructive effects such as exceeding the tolerable current of the
Ahmad Ghafari   +3 more
doaj   +1 more source

Magnetizing Characteristics of Bridge Type Superconducting Fault Current Limiter (SFCL) with Simultaneous Quench Using Flux-Coupling

open access: yesEnergies, 2020
A bridge type superconducting fault current limiter (SFCL) with simultaneous quench using two high-temperature superconducting (HTSC) elements and two coils was fabricated to analyze the fault current limiting characteristics.
Seok-Cheol Ko, Tae-Hee Han, Sung-Hun Lim
doaj   +1 more source

Novel Design of a Hybrid Superconducting Fault Current Limiter with Controlled Solid-State Device

open access: yesJournal of Microwaves, Optoelectronics and Electromagnetic Applications, 2021
Fault current limiters are essential devices used to protect the power system and its equipment against high levels of fault current, which are growing up due to the increase of new power sources.
Henrique K. Miyamoto   +5 more
doaj   +1 more source

Integrated control scheme for induction generator, fault current limiter, and energy storage in wind farms [PDF]

open access: yesمجله مدل سازی در مهندسی, 2018
One of main problems of power systems with doubly fed induction generators (DFIG)-based wind farms is their capability of fault ride through (FRT) and output power fluctuations.
Masoud Esmaili   +2 more
doaj   +1 more source

Analysis on Double Quench and Instantaneous Power of SFCL Using Two Magnetically Coupled Windings According to Winding Direction

open access: yesEnergies, 2020
In this study, the characteristics of the double quench and instantaneous power of a superconducting fault current limiter (SFCL) using two magnetically coupled windings were analyzed.
Seok-Cheol Ko, Tae-Hee Han, Sung-Hun Lim
doaj   +1 more source

TESTS OF HTS 2G SUPERCONDUCTING TAPES USING THE LABVIEW ENVIRONMENT [PDF]

open access: yesApplied Computer Science, 2018
HTS 2G superconducting tapes without stabilizer are used for the construction of superconducting fault current limiters. The characteristics R =f(T) of the superconducting tape is essential for design of superconducting current limiters and analysis of ...
Rafał KWOKA   +2 more
doaj   +1 more source

Simulation of a Low-Voltage Direct Current System Using T-SFCL to Enhance Low Voltage Ride through Capability

open access: yesEnergies, 2022
Owing to the increasing penetration level of distributed energy resources (DER) and direct current (DC) load, the usage of low-voltage direct current (LVDC) systems has expanded to achieve efficient operations.
Kwang-Hoon Yoon   +4 more
doaj   +1 more source

Superconducting Fault Current Limiters for HVDC Systems

open access: yesEnergy Procedia, 2015
AbstractHigh-voltage direct current (HVDC) transmission systems using Voltage-Source Converters (VSC) are widely recognized as offering significant potential for long distance high power delivery, particularly for offshore wind farm connections. One of the barriers for the development of multi-terminal HVDC systems is the lack of technologies which ...
Pei, Xiaoze   +2 more
openaire   +3 more sources

Analysis of the DC Fault Current Limiting Characteristics of a DC Superconducting Fault Current Limiter Using a Transformer

open access: yesEnergies, 2020
Recently, a lot of interesting research has been conducted to solve the fault current problem of the DC system. In long-distance transmission, DC transmission is more economical than AC transmission.
Kang-Cheol Cho   +2 more
doaj   +1 more source

A multiport superconducting fault‐current‐limiting circuit breaker for a flexible DC power grid

open access: yesIET Energy Systems Integration, 2021
The fault current of the high‐voltage and large‐capacity flexible DC power grid has the characteristics of a fast rising rate, high peak value, and large influence area; therefore, fault current suppression equipment suitable for the flexible DC power ...
Weiru Wang   +4 more
doaj   +1 more source