Results 21 to 30 of about 8,951,043 (193)
Operational control and protection implications of fault current limitation in distribution networks [PDF]
Rising short-circuit fault current levels is one of the problems associated with the increased presence of distributed generation (DG) in electrical networks.
Blair, S.M. +3 more
core +3 more sources
Superconducting Fault Current Limiters for HVDC Systems
AbstractHigh-voltage direct current (HVDC) transmission systems using Voltage-Source Converters (VSC) are widely recognized as offering significant potential for long distance high power delivery, particularly for offshore wind farm connections. One of the barriers for the development of multi-terminal HVDC systems is the lack of technologies which ...
Pei, Xiaoze +2 more
openaire +3 more sources
High penetration of Doubly Fed Induction Generator (DFIG) into existing power grid can attribute complex issues as they are very sensitive to the grid faults.
Md. Rashidul Islam +6 more
doaj +1 more source
High level of fault currents has become one of the most challenging issues, along with increased electrical energy consumption and power grid expansion. However, some of the previous work was limited to installing limiters on designs and installing them ...
Isa Hafidz +4 more
doaj +1 more source
Design and application of superconducting fault current limiter in a multiterminal HVDC system [PDF]
Voltage source converter based HVdc (VSC-HVdc) systems are prone to high short-circuit current during transmission line faults. The situation for multiterminal HVdc (MTDC) systems is worse.
Yuan, Weijia +5 more
core +5 more sources
DC distribution systems can provide effective solutions for integrating renewable energy sources in future power systems. The low inertia of the DC distribution system causes several problems regarding stability and fault response.
Doaa M. Yehia, Ibrahim B. M. Taha
doaj +1 more source
Superconducting Fault Current Limiter.
There is disclosed a current limiter having a plurality of current limiting units provided for electric paths constituting a plurality of phases, Each current limiting unit is constituted by a superconducting coil functioning as a first current limiting element formed in a non-inductive winding manner by connecting two superconducting coils in series ...
OHKUMA, Takeshi, IWATA, Yoshihiro
openaire +2 more sources
A saturated iron-core superconducting fault current limiter (SI-SFCL) can significantly limit the magnitude of the fault current and reduce the stress on circuit breakers in direct current (DC) power systems. The SI-SFCL consists of three main parts: one
Van Quan Dao +4 more
doaj +1 more source
Single-stage grid-interfaced PV topologies have challenges with high grid fault currents, despite being more efficient, simpler to implement, and less expensive than two-stage ones.
Rania A. Ibrahim, Nahla E. Zakzouk
doaj +1 more source
In this study, the characteristics of the double quench and instantaneous power of a superconducting fault current limiter (SFCL) using two magnetically coupled windings were analyzed.
Seok-Cheol Ko, Tae-Hee Han, Sung-Hun Lim
doaj +1 more source

