Results 11 to 20 of about 8,951,283 (140)

Analisa Penggunaan Superconducting Fault Current Limiter (SFCL) Untuk Melindungi Peralatan di PT Pindo Deli [PDF]

open access: yesJurnal Teknik ITS, 2015
Increas demand load and power capacity requirement at PT Pindo Deli then the short circuit current that occur will be greater. this can cause damage to electrical equipment located around the point of interrupting and resulting failure of the electrical ...
Yohanes Sabriant Widyo Utomo   +1 more
doaj   +2 more sources

Simulation study of integrated‐gate‐commutated‐thyristor based superconducting hybrid direct current circuit breaker

open access: yesHigh Voltage, 2023
With the development of a distributed generation, direct current (DC) load and energy‐storage equipment, voltage‐source‐converter‐based medium‐voltage DC systems (VSC‐MVDC) have attracted more attention due to its low power consumption, high reliability,
Muhammad Junaid   +6 more
doaj   +2 more sources

Converter non‐blocking DC fault ride‐through and system fast restoration arrangements in R‐L SFCL‐equipped MMC‐M2TDC system

open access: yesIET Generation, Transmission & Distribution
Equipping a DC‐type superconducting fault current limiter (SFCL) in a modular multilevel converter‐based multi‐terminal DC (MMC‐M2TDC) system has the potential to reorganize the protection control arrangements during the DC‐side short‐circuit fault. This
Ji Yirun, Peiqian Guo, Liu Qin
doaj   +2 more sources

Analysis of energy dissipation in resistive superconducting fault-current limiters for optimal power system performance [PDF]

open access: yes, 2011
Fault levels in electrical distribution systems are rising due to the increasing presence of distributed generation, and this rising trend is expected to continue in the future.
Burt, Graeme   +4 more
core   +4 more sources

Superconducting fault current limiter application in a power-dense marine electrical system [PDF]

open access: yes, 2011
Power-dense, low-voltage marine electrical systems have the potential for extremely high fault currents. Superconducting fault current limiters (SFCLs) have been of interest for many years and offer an effective method for reducing fault currents.
Burt, Graeme   +5 more
core   +4 more sources

Current–time characteristics of resistive superconducting fault current limiters [PDF]

open access: yes, 2012
Superconducting fault current limiters (SFCLs) may play an important role in power-dense electrical systems. Therefore, it is important to understand the dynamic characteristics of SFCLs.
Burt, Graeme   +2 more
core   +4 more sources

Implications of fault current limitation for electrical distribution networks [PDF]

open access: yes, 2010
This paper explores the potential future need for fault current limitation in the UK's power system, and some of the technical implications of this change.
Blair, S.M.   +11 more
core   +4 more sources

Analysis on Double Quench and Instantaneous Power of SFCL Using Two Magnetically Coupled Windings According to Winding Direction

open access: yesEnergies, 2020
In this study, the characteristics of the double quench and instantaneous power of a superconducting fault current limiter (SFCL) using two magnetically coupled windings were analyzed.
Seok-Cheol Ko, Tae-Hee Han, Sung-Hun Lim
doaj   +1 more source

Design, Fabrication and Testing of a Superconducting Fault Current Limiter (SFCL) [PDF]

open access: yes, 2011
The purpose of this project was to conduct RD (2) Consult on cryogenic subsystem RD (3) Participate in project conceptual and detailed design reviews; and (4) Guide commercialization by participation on the Technical Advisory Board (TAB). SuperPower's in-kind work for the SFCL will be provided in the following areas: (1) Work with ORNL to develop ...
Gouge, Michael   +2 more
openaire   +2 more sources

Design and application of superconducting fault current limiter in a multiterminal HVDC system [PDF]

open access: yes, 2017
Voltage source converter based HVdc (VSC-HVdc) systems are prone to high short-circuit current during transmission line faults. The situation for multiterminal HVdc (MTDC) systems is worse.
Yuan, Weijia   +5 more
core   +5 more sources