Results 81 to 90 of about 900 (168)
Fault current limiters (FCLs) are essential components in modern power systems for critical protection against the damaging effects of fault currents. With extensive short circuits, routine electrical faults, and an increasing risk of failure due to unprecedented events, the development of different types of FCL has gained attention.
Tamalika Chowdhury +2 more
wiley +1 more source
Modeling the limiting performance of resistive superconductor fault current limiters for 2G HTS tape
Fault currents in power systems force valuable power system elements thermally, electro-dynamically and electromagnetically. Due to the increase in fault current levels, the installation of components resistant to fault currents and the damage of these ...
Muhsin Tunay Gençoğlu, Buğra Yılmaz
doaj
To enhance the stability of a micro-grid under fault conditions, this paper proposes the coordination control of a superconducting magnetic energy storage (SMES), an active superconducting fault current limiter (SFCL), and distributed generation units ...
Lei Chen +8 more
doaj +1 more source
Transition mechanism of an Inductive-resistive Superconducting Fault Current Limiter (IR-SFCL)
Superconducting fault current limiters (SFCL) are protective devices that limit the current in power lines when it suddenly increases above a certain safe level as a consequence of a fault. This element is connected in series with the line and has a null impedance when the line current is below the safe value (limit current) but significative increase ...
null Pilar Suárez +3 more
openaire +1 more source
Presaturated iron‐core fault current limiters for MVDC power system applications
This paper presents design and dynamic performance investigation of a 25 kV full‐scale, modular topology (arranged on the sides of a regular hexagon), medium voltage direct current (MVDC) permanent magnet (PM) biased presaturated fault current limiter (PMFCL).
Ibrahim A. Metwally, Mohamed Eladawy
wiley +1 more source
Experimental study of the normal zone propagation velocity in double-layer 2G-HTS wires by thermal and electrical methods [PDF]
The Normal Zone Propagation Velocity (NZPV) of a double-layer second generation (2G) high temperature superconducting (HTS) wire manufactured by American Superconductor has been measured by electrical and thermal methods, and the results have been ...
, +6 more
core +2 more sources
Voltage source converter-based (VSC-based) DC systems play an important role in connecting large-scale renewable energy and distributed energy, but they are vulnerable to DC short-circuit fault and lacks mature protection devices and appropriate ...
Siyuan Liang +6 more
doaj +1 more source
Analysis of Superconducting Fault Current Limiter in DC System with Renewable Energy Sources [PDF]
Superconducting fault-current limiters (SFCLs) have been the subject of research and development for many years and offer an attractive solution to the problem of rising fault levels in electrical distribution systems.
Ganesh, C. +2 more
core +2 more sources
A modified synchronverter for a weak grid with virtual power circles‐based PQ decoupling scheme
A VSG is essential for ensuring stability of a power systems with high penetration of renewable energies, weak grid. Its control, however, is challenging due to the coupling of the active and reactive power which thus, requires virtual impedance. This article simplifies what type, kind and magnitude of the virtual impedance required to achieve a ...
Daniel Angelo Kisinga +2 more
wiley +1 more source
DESIGN AND ANALYSIS OF VOLTAGE COMPENSATION TYPE OF ACTIVE SUPERCONDUCTING FAULT CURRENT LIMITER [PDF]
This paperpresents the operation principleof voltage compensation type active superconducting fault current limiter (SFCL) for the three phase power transmission system. A voltage compensation typeactive super-conducting fault current limiter is composed
Devidas R. Godase, Sarika V. Tade
core +1 more source