Results 1 to 10 of about 2,346 (205)

Combining finite element and reinforcement learning methods to design superconducting coils of saturated iron-core superconducting fault current limiter in the DC power system. [PDF]

open access: yesPLoS ONE, 2023
A saturated iron-core type superconducting fault current limiter (SI-SFCL) can effectively restrict the magnitude of the fault current and alleviate the strain on circuit breakers in DC power systems.
Chang Soon Kim   +5 more
doaj   +2 more sources

Power flow analysis and optimal locations of resistive type superconducting fault current limiters. [PDF]

open access: yesSpringerplus, 2016
Based on conventional approaches for the integration of resistive-type superconducting fault current limiters (SFCLs) on electric distribution networks, SFCL models largely rely on the insertion of a step or exponential resistance that is determined by a
Zhang X   +6 more
europepmc   +4 more sources

On the advance of SFCL: a comprehensive review

open access: yesIET Generation, Transmission and Distribution, 2019
This study aims to provide a comprehensive review of various superconducting fault current limiters (SFCLs) configurations. Regarding the applied technology, the different types of SFCLs are classified into three groups including quench‐type SFCL, non‐quench‐type SFCL, and composite‐type SFCL.
Mohammad Reza Barzegar-Bafrooei   +2 more
exaly   +2 more sources

Optimal application research of superconducting fault current limiters on medium voltage direct current shipboard power system [PDF]

open access: yesScientific Reports
Medium voltage direct current shipboard power system (MVDC SPS) is the development trend of navy in the future. At present, one of the bottlenecks restricting the development of MVDC SPS is that the short fault. This paper presents a method of applying a
Yunshu Zhou, Li Ren, Ying Xu, Jing Shi
doaj   +2 more sources

Analisa Penggunaan Superconducting Fault Current Limiter (SFCL) Untuk Melindungi Peralatan di PT Pindo Deli [PDF]

open access: yesJurnal Teknik ITS, 2015
Increas demand load and power capacity requirement at PT Pindo Deli then the short circuit current that occur will be greater. this can cause damage to electrical equipment located around the point of interrupting and resulting failure of the electrical ...
Yohanes Sabriant Widyo Utomo   +1 more
doaj   +2 more sources

Pemanfaatan SFCL tipe Bridge untuk Meningkatkan Stabilitas Transien Microgrid dan Economic Feasibility

open access: yesJurnal Nasional Teknik Elektro dan Teknologi Informasi, 2023
Pembangkit energi terbarukan (renewable energy, RE) saat ini banyak digunakan oleh masyarakat sebagai upaya untuk mengurangi emisi. Untuk itu, dikembangkan sistem microgrid bersumber pada RE yang berdampingan dengan energi konvensional.
Roy Bayu Negara   +3 more
doaj   +1 more source

Short Circuit and Recovery Time Tests in a helical bifilar R-SFCL module

open access: yesJournal of Microwaves, Optoelectronics and Electromagnetic Applications, 2021
Superconducting Fault Current Limiter (SFCL) modules with distinct arrangements have been investigated, seeking design and performance enhancements. In this context, this work aims to propose a design for resistive SFCL (R-SFCL) modules, using RE-Ba-Cu-O
Luís M. M. Rocha   +5 more
doaj   +1 more source

Application of Superconducting Fault Current Limiter as a Virtual Inertia for DC Distribution Systems

open access: yesIEEE Access, 2021
DC distribution systems can provide effective solutions for integrating renewable energy sources in future power systems. The low inertia of the DC distribution system causes several problems regarding stability and fault response.
Doaa M. Yehia, Ibrahim B. M. Taha
doaj   +1 more source

Impedance Compensation Method Considering Unbalanced Ground Fault with SFCL in a Power Distribution System

open access: yesEnergies, 2022
As the energy demand increases due to the developing electric power industry, the fault current becomes higher during the fault time. A new approach is needed to reduce a fault current in a power distribution system, since the fault currents influence ...
Yoo-Jung Cho, Sung-Hun Lim
doaj   +1 more source

Combined Operation Analysis of a Saturated Iron-Core Superconducting Fault Current Limiter and Circuit Breaker for an HVDC System Protection

open access: yesEnergies, 2021
Recently, in order to overcome the difficulties of interrupting fault currents in multi-terminal direct current systems (MTDC), studies combining a saturated iron-core type superconducting current limiter (SFCL) and a direct current circuit breaker (DCCB)
Jae-In Lee   +5 more
doaj   +1 more source

Home - About - Disclaimer - Privacy