Results 101 to 110 of about 362,311 (271)

Study on stress distribution of distribution network arresters under complex operating conditions based on electro-thermal-mechanical coupling

open access: yesZhongguo dianli
Zinc oxide arresters are the main devices for preventing lightning strike faults in distribution network lines. In the actual operation process, the operating conditions of arresters are complex and diverse.
Zhenyu WANG   +4 more
doaj   +1 more source

A Low Cost Real-Time Transient Recorder for High Voltage Systems. [PDF]

open access: yesSensors (Basel), 2023
Grebović S   +5 more
europepmc   +1 more source

Current disparity in multi-column surge arresters

open access: yes, 2005
High-voltage surge arresters for high-current, high-energy duty often comprise several parallel ZnO columns. The extreme nonlinearity of the voltage-current characteristics of these columns demands close matching.
Abdul-Malek, Z   +3 more
core   +1 more source

Aspects of moisture ingress in polymer housed surge arresters

open access: yes, 2020
Polymers have been extensively applied in the industry, especially in energy system e.g. due to their good processability and insulation properties.
Da Silva, Daiana Antonio   +3 more
core   +1 more source

Strategies for enhancing sensitivity in lateral flow assays

open access: yesVIEW, EarlyView.
Lateral flow assays (LFAs) are essential for cost‐effective, rapid point‐of‐care diagnostics. However, conventional colourimetric LFAs often lack the sensitivity required for low‐abundance biomarkers. This review evaluates six enhancement strategies: flow modulation, sample preconcentration, advanced reporters, chemical signal amplification, structural
Aylar Eslami Saed   +3 more
wiley   +1 more source

Condition monitoring of metal oxide surge arresters at power distribution

open access: yes, 2018
Metal Oxide Surge Arresters (MOSA) are proven to be reliable protective devices for power distribution and electrical transmission system. MOSA are subjected to electrical ageing or degradation due to constant AC conduction or transient voltages. Leakage
Arshad, SM
core   +1 more source

Analysis of Grading Ring Design Parameters and Heat Sink Numbers Effect on Voltage Distribution and Leakage Current in Metal Oxide Surge Arrester

open access: yesIranian Journal of Electrical and Electronic Engineering, 2014
Metal oxide surge arresters (ZNO) are used widely in power system to protect equipments from over voltages. Non uniform potential distribution leads to the depressed service life and low safe reliability, so grading ring is applied on HV surge arrester ...
M. Khodsuz, M. Mirzaie
doaj  

Return voltage measurement on metal oxide surge arresters

open access: yes, 1999
A number of diagnostics are currently available to monitor the condition of metal oxide surge arresters. Very often a number of these diagnostics do not provide meaningful interpretation about the condition of arresters.
Saha, T. K., Dinh, T. C.
core  

Influence of Octaglycidyl‐POSS on Processing Behavior, Gelation Kinetics, and Thermomechanical Properties of a DGEBA/Polyamidoamine Epoxy System

open access: yesJournal of Vinyl and Additive Technology, EarlyView.
The rigid, octafunctional Si8O12 cage of OG‐POSS incorporates into the DGEBA/polyamidoamine network as a multifunctional junction, raising the glass transition temperature (Tg) by up to 19°C and the apparent crosslink density non‐monotonically by 47%‐71% at 1.5, 3.0, and 5.0 phr loading.
Alex da Silva Sirqueira   +3 more
wiley   +1 more source

A Comprehensive Study on the Quality of Commercially Available Medium Voltage Surge Arresters

open access: yesIEEE Access
This paper presents a comprehensive study on the quality and reliability of commercially available medium voltage surge arresters, with particular emphasis on their electrical performance and structural degradation under aging conditions.
Kuba Wojcik   +8 more
doaj   +1 more source

Home - About - Disclaimer - Privacy