Results 81 to 90 of about 6,473 (191)
Metal oxide surge arresters (ZNO) are used widely in power system to protect equipments from over voltages. Non uniform potential distribution leads to the depressed service life and low safe reliability, so grading ring is applied on HV surge arrester ...
M. Khodsuz, M. Mirzaie
doaj
Glaucoma is increasingly understood as a neurodegenerative disorder shaped by sleep and circadian physiology, not intraocular pressure alone. Sleep loss and obstructive sleep apnea suppress BDNF–TrkB neurotrophic signaling, impair sleep‐dependent glymphatic clearance, and trigger microglial neuroinflammation and vascular insult at the optic nerve head,
Karyme M. Alemán‐Villa +5 more
wiley +1 more source
A Comprehensive Study on the Quality of Commercially Available Medium Voltage Surge Arresters
This paper presents a comprehensive study on the quality and reliability of commercially available medium voltage surge arresters, with particular emphasis on their electrical performance and structural degradation under aging conditions.
Kuba Wojcik +8 more
doaj +1 more source
Driven by halon and high GWP agent phase out, perfluorohexanone is increasingly deployed in enclosures such as data centers, marine machinery spaces, and industrial process lines. This review summarizes application performance, discharge and distribution design, material compatibility, and byproduct control and maps practical gaps for large volume and ...
Zhilei Yu +8 more
wiley +1 more source
Strategies for enhancing sensitivity in lateral flow assays
Lateral flow assays (LFAs) are essential for cost‐effective, rapid point‐of‐care diagnostics. However, conventional colourimetric LFAs often lack the sensitivity required for low‐abundance biomarkers. This review evaluates six enhancement strategies: flow modulation, sample preconcentration, advanced reporters, chemical signal amplification, structural
Aylar Eslami Saed +3 more
wiley +1 more source
ABSTRACT This paper investigates the generation mechanism of quasi‐power‐frequency resonant overvoltage triggered by multiple lightning strikes in high‐voltage alternating current (HVAC) systems equipped with shunt reactors. Based on field measurements from a 500 kV AC system, equivalent and simplified circuit models have been established to analyse ...
Tao Liang +7 more
wiley +1 more source
ABSTRACT To effectively suppress transient overvoltages in HVDC systems, the design and experimental validation of a multi‐module series controllable arrester are presented. The voltage‐limiting performance, series voltage equalisation capability, and robustness under fault conditions in high‐voltage scenarios require further research.
Tai Yang +4 more
wiley +1 more source
Study on the Power‐Frequency Arc Extinction Characteristics of Semi‐Closed Short‐Gap Device
ABSTRACT Multi‐chamber arc‐extinguishing devices have a simple structure and excellent arc‐extinguishing performance; thus, they have attracted considerable attention as lightning protection devices. However, the structural parameters of different models of the aforementioned devices vary, leading to inconsistent protection levels; therefore, the arc ...
Yeqiang Deng +4 more
wiley +1 more source
Installation locations of surge arresters on double-circuit transmission lines
The connected series-compensated capacitors alter the sequence network impedance of transmission lines and the distribution of sequence currents during faults.
YANG Liming +5 more
doaj +1 more source
ABSTRACT High voltage equipment, as a core component of power systems, plays an indispensable role in ensuring the reliability of power supply through its safe and stable operation. Traditional visual defect detection for high voltage equipment, however, often relies on manual inspection and experience‐based judgement, which struggles to meet the ...
Zhenbing Zhao +7 more
wiley +1 more source

