LIGHTNING SIMULATION STUDY ON LINE INSULATORS (Surge arresters) (110kV Overhead Power Line "Fierze F. Arrez - HC Dardhe") [PDF]
During the designing phase of the line of a private power plant was made a study of howthe atmospheric discharges from lighting impulses could affect the working regime of a newpower Hydro Power plant under construction in the Dardhe Puke Area.The line ...
Aldi Mucka, Rejnald Zylfi
core
The adequate protection of the distribution transformers is a critical issue, in an effort to avoid interruption of the power supply and damages of the equipment. The installation of metal oxide gapless surge arresters at the entrance of the transformers
C. Christodoulou, V. Vita, T. Maris
semanticscholar +1 more source
SURGE PROTECTION OF BUILDINGS CONNECTED TO AN OVERHEAD LOW-VOLTAGE NETWORK [PDF]
U prenaponskoj zaštiti na niskom naponu postoje tri klase uređaja prenaponske zaštite. Predstavljena metoda izbora uređaja prenaponske zaštite može se koristiti pri donošenju odluke koje klase treba biti uređaj prenaponske zaštite koji se postavlja u ...
I. Pavić, I. Uglešić, V. Milardić
core +1 more source
Effect of water on electrical properties of Refined, Bleached, and Deodorized Palm Oil (RBDPO) as electrical insulating material [PDF]
This paper describes the properties of refined, bleached, deodorized palm oil (RBDPO) as having the potential to be used as insulating liquid. There are several important properties such as electrical breakdown, dielectric dissipation factor, specific ...
Arief, Yanuar Zulardiansyah +1 more
core
Metal oxide surge arresters (ZNO) are used widely in power system to protect equipments from over voltages. Non uniform potential distribution leads to the depressed service life and low safe reliability, so grading ring is applied on HV surge arrester ...
M. Khodsuz, M. Mirzaie
doaj
A Comprehensive Study on the Quality of Commercially Available Medium Voltage Surge Arresters
This paper presents a comprehensive study on the quality and reliability of commercially available medium voltage surge arresters, with particular emphasis on their electrical performance and structural degradation under aging conditions.
Kuba Wojcik +8 more
doaj +1 more source
A Low Cost Real-Time Transient Recorder for High Voltage Systems. [PDF]
Grebović S +5 more
europepmc +1 more source
The status (2009) of CERN’s Static Var Compensators and the future role of BEQ1/BB3 [PDF]
As of 1 January 2009, CERNs Static Var Compensators have been transferred from EN-EL to TE-EPC. During 2009, the SVC's will be operated jointly by these two groups.
Kahle, K
core
Sessile water droplets on insulating surfaces subject to high AC stress effect of contact angle [PDF]
Surface pollution of outdoor high-voltage insulators is an important cause of flashover. We have undertaken an experimental study of electrical breakdown at the edges of a sessile water droplet on a planar, polymeric, insulating surface when subject to ...
Crichton, B.H. +3 more
core
Installation locations of surge arresters on double-circuit transmission lines
The connected series-compensated capacitors alter the sequence network impedance of transmission lines and the distribution of sequence currents during faults.
YANG Liming +5 more
doaj +1 more source