Results 41 to 50 of about 2,287 (160)
3D‐Printed Corneal Substitutes: Materials, Fabrication, and Preclinical Progress
Successful clinical translation of 3D‐printed corneal substitutes relies on the interplay between the bioink properties, cellular component, and the fabrication process. These factors influence the critical properties of the construct, including optical transparency, mechanical stability, suture retention, that ultimately govern long‐term stromal ...
Shadi Moshayedi +4 more
wiley +1 more source
Steven M Christiansen,1 Mark D Mifflin,1 Jason N Edmonds,1 Rachel G Simpson,2 Majid Moshirfar11John A Moran Eye Center, University of Utah, Salt Lake City, UT, 2The University of Arizona College of Medicine, Phoenix, AZ, USABackground: The purpose of ...
Christiansen SM +4 more
doaj
Context: Various modifications in cataract surgery have been tried to reduce postoperative astigmatism. Incision length and location are some variable modulations.
Shivayogi R. Kusagur +2 more
doaj +1 more source
Understanding higher‐order aberrations in keratoconus
ABSTRACT Keratoconus is characterized by progressive thinning and increasing irregularity of the cornea, leading to substantial degradation in optical quality through the induction of both lower‐ and higher‐order aberrations (HOAs). In addition to inducing myopic and astigmatic refractive error, asymmetric corneal steepening generates complex optical ...
Gavin Swartz +3 more
wiley +1 more source
Introduction: Phacoemulsification is a new and modern cataract surgery; although surgically induced astigmatism is an unavoidable complication. The site of incision is an important factor in complication.
Sayed Mohammad Ghoreishi +2 more
doaj
Short-term outcome of cataract surgery in tertiary hospitals
Background and aim In this study we aimed to assess the short-term outcome of phacoemulsification in a tertiary hospital and to analyze which are the factors affecting visual outcomes. Patients and methods This is a prospective cohort study that included
Nermine M Mahmoud +3 more
doaj +1 more source
Nonthermal plasma approaches for combating implant‐associated infections: A compendious review
Implant‐associated infections pose serious clinical challenges. Non‐thermal plasma (NTP) modifications overcome this bottleneck in distinct ways relative to traditional sterilization methods. Gas‐phase plasmas generate highly energetic species, UV radiation and reactive oxygen/nitrogen species (RONS), which alter the implant surface properties.
A. M. Trimukhe +8 more
wiley +1 more source
Surgically induced astigmatism of small incision cataract surgery [PDF]
No abstract available.DOI: http://dx.doi.org/10.3126/nepjoph.v4i2.6560 Nepal J Ophthalmol 2012; 4 (2): 343
openaire +2 more sources
ABSTRACT Heterozygous variants in the AHDC1 gene are associated with Xia Gibbs Syndrome (XGS), a genetic disorder with a highly variable phenotype. Cognitive impairment, motor delay, language delay, neonatal hypotonia, and sleep apnea are considered “cardinal” signs of the disease.
Giulia Cinelli +18 more
wiley +1 more source
Cataract Surgery Outcomes: Comparison of 2.4 mm and 2.8 mm Clear Corneal Incisions
INTRODUCTION: To compare clinical outcomes of cataract surgeries with 2.4 mm and 2.8 mm clear corneal incisions. METHODS: This retrospective study comprised 2 groups of cataract surgery cases with different wound lenghts of group 1; 2.4 mm and group 2; 2.
Bilal Kavşut +4 more
doaj +1 more source

