Results 91 to 100 of about 255,373 (206)
PURPOSE: To compare the hemodynamic repercussions following a toxic dose of levobupivacaine and bupivacaine intravascularly injected in swines. Methods: Large White pigs were anesthetized with thiopental, tracheal intubation was performed and mechanical ...
Artur Udelsmann +5 more
doaj +1 more source
Invasive hemodynamic monitoring has become standard in the management of aneurysmal subarachnoid hemorrhage. This study is a retrospective analysis of 630 Swan-Ganz catheters placed in 184 patients with aneurysmal subarachnoid hemorrhage.
Getch, C C +3 more
core +1 more source
Left fascicular blocks during right-heart catheterization using the Swan-Ganz catheter.
During insertion of Swan-Ganz catheters, mechanical right bundle branch block occurred in association with left posterior fascicular block in two patients and with left anterior fascicular block in two.
K Pefkaros +13 more
core +1 more source
Background: Mortality in shock may reach 60%; hence, immediate, adequate resuscitation has a crucial role in improving outcomes. Detailed hemodynamic monitoring is desirable, but evidence on its outcome benefits is limited. Therefore, this study aimed to
Liliána Nagy +9 more
doaj +1 more source
A novel technique for invasive aortic valve pressure gradient measurement using a 6 Fr Swan-Ganz catheter: a case series. [PDF]
Agarwal N +3 more
europepmc +1 more source
Is there still a place for the Swan–Ganz catheter? No [PDF]
Teboul, Jean-Louis +2 more
openaire +3 more sources
Pacing Swan-Ganz Catheter in Minimally Invasive Mitral Valve Surgery
The use of a lateral mini-thoracotomy presents several advantages over the standard access, such as less surgical trauma, reduced morbidity and mortality, shorter recovery time and better cosmetic results, but presents difficulties iftemporary pacing is ...
Pitracek, Michael +4 more
core
Medición invasiva del gasto cardíaco en las Unidades de Cuidados Críticos (UCC) [PDF]
The purposes of the haemodynamic monitoring are the proper assesment of the tissue perfusion and oxygenation, the diagnosis of right and left ventricular failure and that of specific lung and cardiac dysfunctions, and also the control of the effects of ...
González Torrijos, J.
core
Cathéter de Swan-Ganz en chirurgie coronarienne à faible risque
Le cathéter de swan-Ganz, outil de monitoring invasif continue de faire l'objet de fréquentes publications quant à son réel intérêt au chevet du malade, et ce dans les domaines médicaux et chirurgicaux.
ROBIN, Sylvaine, GIRARDET, Pierre
core
To evaluate the effect of thoracic epidural anesthesia (TEA) on tissue oxygen delivery and utilization in patients undergoing cardiac surgery. This prospective observational study was conducted in a tertiary referral heart hospital.
Suryaprakash Sharadaprasad +8 more
doaj

