Results 151 to 160 of about 9,819 (207)
Comparison of Artificial Intelligence Models and Human Experts in Managing Dyslipidemia: Assessment of Adherence to Clinical Guidelines. [PDF]
Ucdal M +5 more
europepmc +1 more source
Study protocol for a randomized controlled trial of Regulating Together (RT), a group therapy for emotion dysregulation in school-age autistic youth and their caregivers. [PDF]
McKinney WS +10 more
europepmc +1 more source
Visuo-tactile congruency influences the body schema during full body ownership illusion.
Rubo M, Gamer M.
europepmc +1 more source
Conceptual survey of generators and power electronics for wind turbines [PDF]
Bak-Jensen, B. +7 more
core
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Study on switched reluctance generator
Journal of Zhejiang University-SCIENCE A, 2004The linear and non-linear math models of the switched reluctance generator (SRG) in generator mode were established in this work. The phase current and energy conversion process during generator operation were simulated by the linear math model. The non-linear math model was used to analyze the characteristics of the SRG operation in self-excitation ...
Zai-ping, Pan, Ying, Jin, Hui, Zhang
openaire +2 more sources
Switched Reluctance Starter/Generator
SAE Technical Paper Series, 1992<div class="htmlview paragraph">This paper describes the characteristics of the switched reluctance motor (SRM) used as a generator. In this mode of operation the SRM is unique in that it does not employ permanent magnets or a field winding on its rotor.
Arthur Radun, James Rulison, Peter Sanza
openaire +1 more source
Self-excited switched reluctance generator
XI Brazilian Power Electronics Conference, 2011This paper presents a study on the behavior of the self-excited switched reluctance generator (SSRG). Following an extensive bibliographic review about SSRGs, the mathematical model, principle of operation and simulation results of the generator dynamics is presented. A capacitor partially charged, in parallel with the load is used as a mean to provide
V. R. Bernardeli +5 more
openaire +1 more source
Closed‐loop control of switched reluctance generators
COMPEL - The international journal for computation and mathematics in electrical and electronic engineering, 2005PurposeThis paper deals with closed‐loop control of a switched reluctance generator (SRG).Design/methodology/approachThe control objective when generating is to maintain the dc link voltage at the required value while achieving maximum efficiency.
Kennedy, E. P. +3 more
openaire +2 more sources

