Acoustic carrier signal transmission technology and its potential for in‐site monitoring of sliding electrical contact used in gas‐insulated switchgear/gas‐insulated transmission line [PDF]
Chen Chen +4 more
openalex +1 more source
ABSTRACT In this paper, a model‐aided state parameter inversion identification method based on the coil current (CC) of electromagnetic trip device (ETD) is proposed to realise the state parameter inversion online and the quantitative description of defects.
Feiyue Yan +3 more
wiley +1 more source
Partial discharges measurement by UHF method [PDF]
The unconventional UHF (Ultra High Frequency) method of measuring partial discharges (PD) is based on measuring electromagnetic waves (EM) in the UHF frequency band (300-3000) MHz, using appropriate antennas.
Malešević Nevena +3 more
doaj
A Multi-Objective Planning Framework for Optimal Integration of Distributed Generations [PDF]
This paper presents an evolutionary algorithm for analyzing the best mix of distributed generations (DG) in a distribution network. The multi-objective optimization aims at minimizing the total cost of real power generation, line losses and CO2 emissions,
Howe, Joe +2 more
core +1 more source
ABSTRACT Surface discharge is a typical fault type in electric power equipment. High temperature in long‐term operation can easily lead to ageing of materials, resulting in changes in surface characteristics and surface discharge faults. In this paper, a method of surface discharge identification of silicon rubber (SiR) based on spectral detection ...
Yanze Han +6 more
wiley +1 more source
The development of renewable energies and smart mobility has profoundly impacted the future of the distribution grid. An increasing bidirectional energy flow stresses the assets of the distribution grid, especially medium voltage switchgear.
Martin W. Hoffmann +16 more
doaj +1 more source
Nondestructive Measurement of Residual Stress on Epoxy Insulators Using Thermoelastic Method
ABSTRACT Residual stress is inevitable in epoxy insulators, which easily leads to small cracks and even insulation breakdown during the operation of gas‐insulated transmission line (GIL)/gas‐insulated switchgear (GIS). This study proposes a nondestructive method to measure the residual stress on epoxy insulators using thermoelastic effects.
Hucheng Liang, Bei Chu, Boxue Du
wiley +1 more source
Accurate calculation of short‐circuit electromagnetic force is crucial for both mechanical strength check and the optimal design of gas‐insulated transmission lines (GIL).
Shucan Cheng +3 more
doaj +1 more source
ABSTRACT Many researchers are committed to improving the diagnosis accuracy and solving the few‐shot problem on circuit breakers (CBs). However, the research on the vibration transmission mechanism of the fault is insufficient, which makes it difficult to find the potential design defects of CBs through vibration.
Jiayi Gong +3 more
wiley +1 more source
Restrike characteristics of vacuum circuit breaker in its opening process under DC voltage
The restrike of vacuum circuit breaker during the breaking process causes overvoltage and intensifies the insulation deterioration of high‐voltage equipment. To solve this problem, the vacuum breaker aging test method and the restrike characteristics are
Jixing Sun +8 more