Results 61 to 70 of about 30,341 (295)

Partial discharges measurement by UHF method [PDF]

open access: yesZbornik Radova: Elektrotehnički Institut "Nikola Tesla", 2020
The unconventional UHF (Ultra High Frequency) method of measuring partial discharges (PD) is based on measuring electromagnetic waves (EM) in the UHF frequency band (300-3000) MHz, using appropriate antennas.
Malešević Nevena   +3 more
doaj  

Estimate the Temperature Rise of Medium Voltage Metal Enclosed Switchgear by Simplified Heat Transfer Calculations

open access: yesIEEE Transactions on Power Delivery, 2021
Electrical equipment will experience a rise in temperature during normal operation. During a development process, prototypes and laboratory tests will be required to make sure the temperature rises are within acceptable limits as defined by standards ...
E. Fjeld   +3 more
semanticscholar   +1 more source

Surface flashover in 50 years: II. Material modification, structure optimisation, and characteristics enhancement

open access: yesHigh Voltage, Volume 10, Issue 2, Page 243-278, April 2025.
Abstract Surface flashover is a gas–solid interface insulation failure that significantly jeopardises the secure operation of advanced electronic, electrical, and spacecraft applications. Despite the widespread application of numerous material modification and structure optimisation technologies aimed at enhancing surface flashover performance, the ...
Zhen Li   +4 more
wiley   +1 more source

Seismic evaluation of ±800 kV UHVDC disconnect switch by shake table test

open access: yesThe Journal of Engineering, 2019
Disconnect switches, the widely used electrical substation apparatuses, however, were severely damaged in several earthquakes, causing huge economic losses.
Jiayi Wen, Qiang Xie
doaj   +1 more source

Restrike characteristics of vacuum circuit breaker in its opening process under DC voltage

open access: yesIET Science, Measurement & Technology, 2023
The restrike of vacuum circuit breaker during the breaking process causes overvoltage and intensifies the insulation deterioration of high‐voltage equipment. To solve this problem, the vacuum breaker aging test method and the restrike characteristics are
Jixing Sun   +8 more
doaj   +1 more source

Temperature rise characteristics of C5F10O/CO2 gas mixture AC high voltage switch bus

open access: yesHigh Voltage, Volume 10, Issue 2, Page 325-336, April 2025.
Abstract C5F10O/CO2 gas mixture is one of the most promising alternatives to SF6 as an insulating gas in high‐voltage switchgear. As a key performance index in product design, the temperature rise characteristics are rarely reported. In this paper, the thermodynamic parameters of C5F10O/CO2 gas mixture were calculated first. Then, the calculation model
Zhaoxuan Cui   +5 more
wiley   +1 more source

A novel multi‐slice electromagnetic field‐circuit coupling method for transient computation of long‐distance gas‐insulated transmission lines

open access: yesHigh Voltage
Accurate calculation of short‐circuit electromagnetic force is crucial for both mechanical strength check and the optimal design of gas‐insulated transmission lines (GIL).
Shucan Cheng   +3 more
doaj   +1 more source

Fabrication of insulation spacers for ultra‐high voltage gas‐insulated switchgear using eco‐friendly bio‐based epoxy composite material characterisation evaluation

open access: yesHigh Voltage, Volume 10, Issue 2, Page 451-457, April 2025.
Abstract In the electric power equipment industry, various insulating materials and accessories are manufactured using petroleum‐based epoxy resins. However, petrochemical resources are gradually becoming limited. In addition, the global surge in plastic usage has consistently raised concerns regarding greenhouse gas emissions, leading to worsening ...
Chanyong Lee   +3 more
wiley   +1 more source

STUDI TENTANG SISTEM INTERLOCKING PADA GAS INSULATED SWITCHGEAR(GIS) 500 KV DI PLTU PAITON UNIT 7 DAN 8 [PDF]

open access: yes, 2010
Electrical energy is one of energy that has the role in all sectors so that the availability of power required by large amount as well as sustainable. PLTU Paiton Unit 7 and 8 is one of the private power company that attempts to meet the high demand for ...
., Jasmadi   +4 more
core  

The Development of Computer-Aided Design for Electrical Equipment Selection and Arrangement of 10 Kv Switchgear

open access: yesMATEC Web of Conferences, 2015
The paper intends to give an overview of a computer-aided design program application. The research includes two main parts: the development of a computer-aided design for an appropriate switchgear selection and its arrangement in an indoor switchgear ...
Chernaya Anastassiya, Sokolova Elvira
doaj   +1 more source

Home - About - Disclaimer - Privacy