Results 71 to 80 of about 31,506 (294)
Accurate calculation of short‐circuit electromagnetic force is crucial for both mechanical strength check and the optimal design of gas‐insulated transmission lines (GIL).
Shucan Cheng+3 more
doaj +1 more source
Seismic evaluation of ±800 kV UHVDC disconnect switch by shake table test
Disconnect switches, the widely used electrical substation apparatuses, however, were severely damaged in several earthquakes, causing huge economic losses.
Jiayi Wen, Qiang Xie
doaj +1 more source
STUDI TENTANG SISTEM INTERLOCKING PADA GAS INSULATED SWITCHGEAR(GIS) 500 KV DI PLTU PAITON UNIT 7 DAN 8 [PDF]
Electrical energy is one of energy that has the role in all sectors so that the availability of power required by large amount as well as sustainable. PLTU Paiton Unit 7 and 8 is one of the private power company that attempts to meet the high demand for ...
., Jasmadi+4 more
core
A convolutional neural network based deep learning methodology for recognition of partial discharge patterns from high voltage cables [PDF]
It is a great challenge to differentiate partial discharge (PD) induced by different types of insulation defects in high-voltage cables. Some types of PD signals have very similar characteristics and are specifically difficult to differentiate, even for ...
Bhatti, Ashfaque Ahmed+11 more
core +4 more sources
Abstract CF4 is a major decomposition product of the insulating gas in C4F7N‐insulated gas‐insulated metal‐enclosed switchgear (GIS) during partial discharge or overheating faults. Its detection is essential for effective online monitoring and fault diagnosis of GIS.
Zhicheng Wu+6 more
wiley +1 more source
The paper intends to give an overview of a computer-aided design program application. The research includes two main parts: the development of a computer-aided design for an appropriate switchgear selection and its arrangement in an indoor switchgear ...
Chernaya Anastassiya, Sokolova Elvira
doaj +1 more source
Abstract Within 30 min after live operation of gas‐insulated switchgear (GIS), more than 60% of discharge failures are caused by metallic particles. To address this issue, this study explored the vibration propagation mechanisms in GIS cavities and established an equivalent vibration transmission model.
Jian Wang+7 more
wiley +1 more source
Flexible electrical conductors for high-temperature switchgear [PDF]
Arch-shaped conductors fabricated from flat strips of beryllium oxide dispersion-strengthened copper alloy serve as flexible electrical connectors capable of operating in 1000 deg F temperature range, under vacuum conditions for periods of 10,000 hours ...
Koutnik, E. A.+2 more
core +1 more source
Abstract Surface flashover is a gas–solid interface insulation failure that significantly jeopardises the secure operation of advanced electronic, electrical, and spacecraft applications. Despite the widespread application of numerous material modification and structure optimisation technologies aimed at enhancing surface flashover performance, the ...
Zhen Li+4 more
wiley +1 more source
Temperature rise characteristics of C5F10O/CO2 gas mixture AC high voltage switch bus
Abstract C5F10O/CO2 gas mixture is one of the most promising alternatives to SF6 as an insulating gas in high‐voltage switchgear. As a key performance index in product design, the temperature rise characteristics are rarely reported. In this paper, the thermodynamic parameters of C5F10O/CO2 gas mixture were calculated first. Then, the calculation model
Zhaoxuan Cui+5 more
wiley +1 more source