Analysis on switching overvoltage of 500 kV GIS disconnector
The 500 kV GIS disconnector of a pumped storage power station is detected to have the risk of operating overvoltage breakdown of the gas chamber. In this paper, the causes of the operating overvoltage of the disconnector of GI equipment are analyzed, and
Hongtao Ren
doaj +4 more sources
Analysis of the Zero Overvoltage Switching Phenomenon
In common understanding, the fast switching speed of wide-bandgap devices leads to high overvoltage and oscillations, if no countermeasures are taken. Those countermeasures were introduced in the past, and include methods such as build-in gate resistors ...
Nico Schmied, Stefan Matlok, Martin Marz
doaj +3 more sources
Analysis on switching overvoltage and suppression method of cable joint in 500 kV cable line
The breakdown accident of cable joint occurs frequently when the sheath overvoltage cable line is closed, but the cable joint is ignored or simply treated in the previous overvoltage simulation of cable system.
Hongtao Ren, Ying Zhang
doaj +3 more sources
Analysis of suppression switching overvoltage for CRAFT power supply
In order to solve the problem of switching overvoltage for CRAFT, an optimal design is put forward to suppress overvoltage, which aims to enable the converter thyristor work normal.
Yalong Yang +4 more
doaj +3 more sources
When a high‐speed train approaches the insulated phase‐splitting section embedded between neighbouring power supply arms, the vacuum circuit breaker (VCB) installed on trains must be disconnected to maintain the traction power supply system as a no‐load ...
Ye Cao +13 more
doaj +2 more sources
Novel method for restraining 35 kV shunt reactor switching overvoltage – phase controlled breaker
Phenomena such as current chopping, arc reignition and equivalent current chopping might appear when cutting off shunt reactor. Overvoltage caused by switching will lead to interphase fault in related equipment and inter-turn insulation damage in the ...
Yiming Zheng +5 more
doaj +2 more sources
The multiple reignitions of vacuum circuit braker (VCB) while switching off the shunt reactor in an offshore wind farm (OWF) would produce a high overvoltage. The post‐arc process of ion movement in the vacuum interrupter is analysed.
Zhi Zheng +5 more
doaj +2 more sources
This paper investigates the impact factors of switching transient overvoltage (SOV) in an offshore wind farm (OWF) by analyzing multiple ignitions of a vacuum circuit breaker.
Jiujiang Zhou +4 more
doaj +2 more sources
Peducing the frequency of switching overvoltage in generator networks
THE PURPOSE of the study is to study the problem of switching overvoltages in 10 kV generator networks. Using the Matlab Simulink package, create a model of common auxiliaries of a 10/0.4 kV power station, calculate the overvoltage at different sections ...
R. A. Belsky +3 more
doaj +2 more sources
The emergence of fast-switching wide-bandgap (GaN, SiC) power electronics devices has enabled motor drive systems to achieve high efficiency, power density, control bandwidth and high-level of integration.
Yipu Xu +6 more
doaj +1 more source