Results 41 to 50 of about 7,296,413 (350)
The paper analyses how the characteristics of the medium-voltage network with insulated neutral and the conditions under which the single line-to-ground fault occurs (insulation condition and value of the fault resistance) influence the zero-sequence ...
Dumitru Toader +4 more
doaj +1 more source
Three-phase circuits that are Symmetrically Configured in the Narrow Sense (SCNS) have been defined in previous works as circuits which dq0 dynamic model does not depend on the transformation’s reference angle.
Elior Segev +4 more
doaj +1 more source
Identification of fault locations in capacitor banks is still under development. Although, faults in capacitor banks can be detected by an unbalance relay, it cannot identify the fault location.
Praikanok Lertwanitrot +1 more
doaj +1 more source
Faults in electrical networks are among the key factors and sources of network disturbances. Control and automation strategies are among the key fault clearing techniques responsible for the safe operation of the system. Several researchers have revealed
Aphrodis Nduwamungu +3 more
doaj +1 more source
The lineshape of crystal-field transitions in single crystals of Mn12ac molecular magnets is determined by the magnetic history. The absorption lines are symmetric and Gaussian for the non-magnetized state obtained by zero-field cooling (zfc).
A. Caneschi +32 more
core +1 more source
Field theory of massive and massless vector particles in the Duffin - Kemmer - Petiau formalism
Field theory of massive and massless vector particles is considered in the first-order formalism. The Hamiltonian form of equations is obtained after the exclusion of non-dynamical components.
Ahieser A. I. +12 more
core +1 more source
Fault-Tolerant Controller Applied to a Wind System Using a Doubly Fed Induction Generator
Wind systems are sustainable and economical options for producing electrical energy. These systems efficiently manage the power flow by maximizing wind power and consuming reactive power from the grid.
Onofre Morfín +5 more
doaj +1 more source
Analysis of drawbacks and constraints of classification algorithms for three-phase voltage dips [PDF]
Voltage events are one of the most common and harmful disturbances of power electric systems. Voltage dips, swells and interruptions are included under this heading.
Carrica, Daniel Oscar +5 more
core +1 more source
Performance Investigation of Three-Phase Three-Switch Direct PWM AC/AC Voltage Converters
Reducing the number of active switches is substantial for obtaining a simple, reliable, high-efficiency, and cost-effective AC/AC voltage converter. In this paper, two topologies of three-phase direct PWM AC/AC voltage converter are proposed.
Said A. Deraz +4 more
doaj +1 more source
Symmetrical Components Digital Filters for Microprocessor-Based Protection Input Signals
In microprocessor protections, measuring bodies are used that react to individual symmetrical components of signals or a combination of them. This makes the corresponding protection devices more sensitive.
F. A. Romaniuk +2 more
doaj +1 more source