Results 231 to 240 of about 169,903,045 (266)
Some of the next articles are maybe not open access.

Research on Active Magnetic Shielding for Electric Vehicle Wireless Power Transfer System

2023 2nd International Conference on Futuristic Technologies (INCOFT), 2023
Jinxue Meng, Junnan Tian, Ming Cai
exaly   +2 more sources

Actively shielded transportable SMES-systems

IEEE Transactions on Magnetics, 1996
Previous investigations on active shielding of SMES systems have proved to be successful in reducing the stray field. It was shown that the stray field of a single solenoidal SMES can be diminished by adding shielding solenoids under the condition that the sum of the magnetic dipole moments of all coils equals zero.
G. Fresacher, G. Schonwetter, J. Gerhold
openaire   +1 more source

Shielding factor enhancement method for Bi-stage active shield in SQUID-based Magnetocardiography system

2021 29th Iranian Conference on Electrical Engineering (ICEE), 2021
We proposed a simple method to enhance shielding factor of our previously proposed bi-stage active shield system employed in a SQUID-based magnetocardiography system. The additional proposed design is optimized for canceling the power-line magnetic interference field to provide a calmer magnetic environment for the bi-stage active shield.
Zeynab Alipour   +3 more
openaire   +1 more source

Active shielding suitable for electron beam lithography systems

Digest of INTERMAG 2003. International Magnetics Conference (Cat. No.03CH37401), 2003
This paper describes suitable active shielding (AS) for electron-beam lithography systems (EBLSs). The optimal position of a reference sensor (RS), of which the signal is used to feed a current into a canceling coil (CC), is discussed. Preliminary experiments using an EBLS verification model and three-dimensional (3-D) magnetic field computations were ...
K. Yamazaki   +9 more
openaire   +1 more source

Low Noise Active Shield for SQUID-Based Magnetocardiography Systems

IEEE Transactions on Applied Superconductivity, 2018
A light weight and low-cost active magnetic shield system is proposed for a single channel SQUID-based magnetocardiography system equipped for operating at liquid nitrogen temperature without passive magnetic shield. The developed active shield, using coils around the sensors, is a two-stage magnetic shielding system, each stage of which has been ...
Faezeh Shanehsazzadeh, Mehdi Fardmanesh
openaire   +1 more source

Operational experiences of active shielding systems for overhead HV lines

2012 IEEE International Energy Conference and Exhibition (ENERGYCON), 2012
In the framework of reducing the impact of the electric system infrastructure, the paper presents the successful field application of the principle of active shielding of the magnetic field of HV overhead lines. Two plants have been deployed and are currently being operated since some years on a 132kV and a 400kV line.
GIGLIOLI, ROMANO   +3 more
openaire   +2 more sources

Active Shielding Design of Patrol Robot Wireless Charging System

2019 IEEE 3rd International Electrical and Energy Conference (CIEEC), 2019
The wireless charging technology (WPT) is a hot research topic at present. Because of its plug-in-free feature, it is very suitable for patrol robots. In order to reduce the influence of wireless charging coupling mechanism on electromagnetic environment in non-working area, a shielding device was designed and its finite element model (FEM) was ...
Yifan Nie, Chaoqun Jiao, Yuanliang Fan
openaire   +1 more source

An actively shielded gradient coil design for use in planar MRI systems with limited space

Review of Scientific Instruments, 2018
In planar magnetic resonance imaging (MRI) systems, gradient coils are usually placed within a very limited space owing to the physical constraints of the small gap size (pole-pole) distance of the permanent magnet. Typically, the unshielded or partially shielded design scheme is adopted to generate required magnetic fields with reduced system costs ...
Yaohui Wang   +5 more
openaire   +5 more sources

Mobile Cryocooler-Based SQUID NDE System Utilizing Active Magnetic Shielding

IEEE Transactions on Appiled Superconductivity, 2005
A mobile cryocooler-based SQUID NDE system was developed for realization of NDE of fixed targets that can't be moved or rotated. In order to move the SQUID in an ambient field, an active magnetic shielding technique employing a compensation coil and feedback circuit including a band elimination filter was introduced in a SQUID NDE system. The HTS SQUID
Y. Hatsukade   +3 more
openaire   +1 more source

Actively shielded gradient coil design for an all-superconducting planar MRI system using progressively-enhanced shielding constraints

Magnetic Resonance Imaging
Strong shielding of gradient coils is required to maintain the cryogenic stability of superconducting magnetic resonance imaging (MRI) systems. In planar-type superconducting MRI systems, which extensive use high-conductivity materials, gradient coil sets are embedded within the open slots of the main magnet.
Yin, Yiqing   +8 more
openaire   +4 more sources