Results 31 to 40 of about 11,464,348 (142)

Repositioning of the Insertable Cardiac Monitor Through the Same Incision to Avoid T-wave Oversensing. [PDF]

open access: yesCureus
Insertable cardiac monitor (ICM), used for long-term heart rhythm monitoring, often experiences diagnostic challenges such as T-wave oversensing, leading to false positives. This case report presents a novel approach to rectifying T-wave oversensing in ICM implantations. In this case, we are sharing a 38-year-old female with recurrent syncopal episodes
Daloub S, Alzubi AS, Abozguia K.
europepmc   +3 more sources

WEC Scale Model Build & Test: Fabrication and Wave Laboratory Testing of 1/10 Scale Wave Energy Conversion Device

open access: yes
Neptune Wave Power, LLC (‘NWP’), worked with OWET, the Northwest National Marine Renewable Energy Center (‘NNMREC’) and Oregon State University (O.H. Hinsdale Wave Research Laboratory) to build and test a 1/10 scale model wave energy conversion (‘WEC ...
Neptune Wave Power LLC   +1 more
core   +6 more sources

2011-2013 Biennial Report [PDF]

open access: yes
Oregon Wave Energy Trust (OWET) is a nonprofit public-private partnership funded by the Oregon Innovation Council. Its mission is to support the responsible development of wave energy in Oregon. OWET emphasizes an inclusive, collaborative model to ensure
Oregon Wave Energy Trust
core   +6 more sources

Myocardial ischemic hyperacute T-wave oversensing leading to a defibrillator shock storm. [PDF]

open access: yesProc (Bayl Univ Med Cent), 2015
Appropriate sensing is essential for the normal functioning of an implantable cardioverter defibrillator (ICD). T-wave oversensing is a potential clinical problem in ICD patients that may result in inappropriate shocks. Oversensing may have various underlying causes and can be treated with noninvasive or invasive means. We present the case of a 45-year-
Chhabra L, Khalid N, Kluger J.
europepmc   +4 more sources

SMART pass will prevent inappropriate operation of S‐ICD

open access: yesJournal of Arrhythmia, 2019
Background Compared to screening ECG before implantation of a subcutaneous implantable cardioverter‐defibrillator (S‐ICD), selectable vectors without T‐wave oversensing increase after S‐ICD implantation. Newer algorithms have recently become available to
Motomi Tachibana   +7 more
doaj   +1 more source

Development of ventricular fibrillation after implantation of a biventricular implantable cardioverter defibrillator: what is the mechanism?

open access: yesClinical Case Reports, 2017
Key Clinical Message Syncopal spells in heart failure patient with cardiovascular implantable electronic devices (CIED) require multiple assessments.
Diego Chemello   +3 more
doaj   +1 more source

Strategy to Eliminate Inappropriate Shocks Secondary to T‐Wave Oversensing in a Biventricular ICD [PDF]

open access: yesPacing and Clinical Electrophysiology, 2008
T‐wave oversensing represents a common cause of inappropriate shocks in patients with implanted cardiac defibrillators. This case report demonstrates a strategy of device programming using V‐V pace delay (sequential rather than simultaneous biventricular pacing) to eliminate T‐wave oversensing without decreasing sensitivity to detect true ...
Jonathan S, Silver   +2 more
openaire   +2 more sources

Expert Consensus Statement: Committee on Implantable Devices and Committee on Social Issues, Japanese Heart Rhythm Society (JHRS) Statement on Remote Monitoring of Cardiac Implantable Electronic Devices

open access: yesJournal of Arrhythmia, Volume 42, Issue 5, October 2026.
This statement of the Japanese Heart Rhythm Society (JHRS) provides comprehensive guidance for medical professionals and device manufacturers involved in RM. ABSTRACT Remote monitoring (RM) has been established as a standard tool for the management of patients with cardiac implantable electronic devices (CIEDs), offering advantages such as early event ...
Eiichi Watanabe   +10 more
wiley   +1 more source

Successful Extensive Pulsed Field Ablation for Atrial Fibrillation Without Leadless Pacemaker Interference

open access: yesJournal of Arrhythmia, Volume 42, Issue 5, October 2026.
Although Pulsed field ablation (PFA) has demonstrated efficacy for atrial fibrillation, its safety in patients with leadless pacemaker remains uncertain. This case suggests that extensive PFA involving persistent left superior vena cava, superior vena cava, and left atrial posterior wall can be safely performed without device interference.
Gen Matsuura   +4 more
wiley   +1 more source

Importance of exercise testing shortly after subcutaneous implantable cardioverter-defibrillator implantation in patients with Brugada syndrome – The first case of associated inappropriate shock in Japan

open access: yesJournal of Arrhythmia, 2017
We report the case of a 51-year-old patient with Brugada syndrome (BrS) who experienced inappropriate shock due to T-wave oversensing (TWOS) during exercise when the optimal sensing vector was selected based on the automatic analysis by a subcutaneous ...
Kohei Ishibashi, MD, PhD   +6 more
doaj   +1 more source