Results 51 to 60 of about 11,464,348 (142)
ABSTRACT Boston Scientific reported that dual chamber INGENIO family pacemakers or cardiac resynchronization therapy pacemakers (CRT‐P) may initiate safety mode. Once Safety Mode is activated, telemetry with the programmer becomes unavailable. This case highlights worsening heart failure due to loss of atrioventricular synchronization associated with ...
Yuki Osada +4 more
wiley +1 more source
SEEING WHAT IS NOT THERE: T-WAVE OVERSENSING IN AN IMPLANTABLE CARDIOVERTER DEFIBRILLATOR
Several mechanisms can result in bradycardia in patients with cardiac rhythm management (CRM) devices. Here we present a case of inappropriate bradycardia due to T-wave oversensing (TWO). A 58 year-old male with paroxysmal atrial fibrillation, hypertrophic obstructive cardiomyopathy status ...
Tahmina Samad +2 more
openaire +1 more source
Atrial Tram Tracks and Ventricular Step Ladder: Decoding the Dot Plot
Falsely detected atrial tachycardia episode in a patient with CRT‐P due to FFRW oversensing resulting in ventricular sensed response triggered BiV pacing and auto adjusting sensitivity phenomenon.
Ramanathan Velayutham +3 more
wiley +1 more source
Oregon Wave Energy Trust (OWET) is a nonprofit public-private partnership funded by the Oregon Innovation Council. Its mission is to support the responsible development of wave energy in Oregon. OWET emphasizes an inclusive, collaborative model to ensure
Oregon Wave Energy Trust
core +6 more sources
Contemporary Perspectives on J‐Wave Syndromes: An Expert Consensus Statement
ABSTRACT J‐wave syndromes (JWS)—comprising Brugada syndrome (BrS) and early repolarization syndrome (ERS)—are important causes of malignant ventricular arrhythmias and sudden cardiac death in patients whose hearts appear structurally normal. Since the 2016 consensus, advances in genetics, pathophysiology, and therapy have redefined both understanding ...
Koonlawee Nademanee +22 more
wiley +1 more source
ABSTRACT Background Implantable cardioverter defibrillator (ICD) therapy can prevent sudden cardiac death, but poses a risk of inappropriate device therapy (IDT), which is linked to worse outcomes and reduced quality of life. On the other hand, ICDs can function as an early warning system for atrial arrhythmias.
Marthe J. Huntelaar +6 more
wiley +1 more source
When the Pacemaker Goes Rogue: Pacemaker‐Induced Tachycardia, Syncope, and Car Crash
A 78‐year‐old male with a history of ischemic heart disease with prior myocardial infarction, severe left ventricular systolic dysfunction, and a device‐related implantable cardioverter defibrillator (DR ICD) was admitted following a road traffic accident due to a sudden loss of control of the vehicle following a syncope.
Hanna Grogg +7 more
wiley +1 more source
Comparative outcomes of subcutaneous and transvenous cardioverter-defibrillators
. Background:. The comparative outcomes of subcutaneous implantable cardioverter-defibrillator (S-ICD) and transvenous ICD (T-ICD) have not been well studied. The aim of this study was to evaluate the safety and efficacy of currently available S-ICD and
Jin-Jun Liang +14 more
doaj +1 more source
Background The number of patients with implantable cardioverter‐defibrillators (ICDs) is steadily increasing, making encounters with ICD‐related emergencies more frequent in prehospital care. Paramedics are often the first healthcare professionals to manage these situations; however, data on their exposure to ICD‐related emergencies and access to ...
Wojciech Telec +7 more
wiley +1 more source
ABSTRACT This case report details the successful implantation of a subcutaneous implantable cardioverter‐defibrillator (S‐ICD) in a 70‐year‐old male with situs inversus dextrocardia, a rare congenital condition where the heart and visceral organs are reversed. The patient, with a history of ischemic heart disease and severe left ventricular dysfunction
Bahareh Karimian +3 more
wiley +1 more source