Results 11 to 20 of about 21,102 (303)

Temporal Profiling of M-TEER-Related Complications [PDF]

open access: yesESC Heart Failure
Abstract Aims Transcatheter edge-to-edge repair of the mitral valve (M-TEER) is known for its low complication rates. However, the optimal level and duration of post-procedural care remain unclear.
Jafer Haschemi   +8 more
openaire   +4 more sources

Change in TEER Value (%). [PDF]

open access: yes, 2022
Change in TEER Value (%).
Ryosuke Miyasaka (6623258)   +2 more
core   +1 more source

A Low-Cost and Customizable TEER Meter for the Measurements of Cellular Barrier Integrity [PDF]

open access: yes, 2019
A low-cost and translational TEER (trans-endothelial/epithelial electric resistance) meter was designed, fabricated, validated, and applied in this paper. TEER is a critical tool to quantitate the integrity of biological barriers.
Curtis G. Jones (8129254)   +3 more
core   +3 more sources

Effect of TNFα on TEER at 24 h and effect of Dex and RU486, a glucocorticoid receptor antagonist, on TEER (not relative value) in alveolar epithelial cells (AECs). [PDF]

open access: yes, 2023
(A) TEER in AECs stimulated with ± 10 ng/mL recombinant rat TNFα for 24 h, n = 6 (six independent experiments). (B) TEER in AECs stimulated with ± 10 ng/mL recombinant rat TNFα for 48 h and ± 1,000 nM Dex for 24 h, n = 6 (six independent experiments). (C)
Koichiro Asano (3438395)   +5 more
core   +1 more source

Transesophageal Echocardiography for Mitral Valve Transcatheter Edge-to-Edge Repair

open access: yesJournal of the Indian Academy of Echocardiography & Cardiovascular Imaging, 2022
Transcatheter edge-to-edge repair (TEER) has emerged as a viable treatment option for patients with degenerative or functional severe mitral regurgitation (MR) who are at high risk for mitral valve surgery but have mitral valve anatomy suitable for TEER.
Nitin J Burkule, Manish Bansal
doaj   +1 more source

Physical and Tribological Properties of Nitrided AISI 316 Stainless Steel Balls

open access: yesMATEC Web of Conferences, 2016
AISI 316 austenitic stainless steel balls (diameters 5.0 and 12.0 mm, typical hardness 250 HV0.3) and flat samples (20×20×2.0 mm) were nitrided by a pulsed glow discharge Ar/N2 plasma. Hardness of the ball surfaces was analysed using Vickers indentation.
Yang Shicai   +4 more
doaj   +1 more source

Draft genome of the river water buffalo

open access: yesEcology and Evolution, 2019
Water buffalo (Bubalus bubalis), a large‐sized member of the Bovidae family, is considered as an important livestock species throughout Southeast Asia.
Abdul Awal Mintoo   +14 more
doaj   +1 more source

Evaluation of Caco-2 and human intestinal epithelial cells as in vitro models of colonic and small intestinal integrity

open access: yesBiochemistry and Biophysics Reports, 2022
Although the colonic cell line Caco-2 is widely used as a model of the small intestinal barrier function, it has limitations such as overestimated transepithelial electrical resistance (TEER) compared to in vivo conditions.
Silvia Lopez-Escalera, Anja Wellejus
doaj   +1 more source

The role of informal networks in the lives of young people transitioning from care: a review of the literature

open access: yesScottish Journal of Residential Child Care, 2021
Young people leaving the care system face significant challenges when making the transition to adulthood, with limited support from other agencies. Their outcomes are significantly poorer than those of their non-care peers. This review aims to synthesise
Philip Teer
doaj   +1 more source

Catheter ablation of concomitant atrial fibrillation improves survival of patients undergoing transcatheter edge-to-edge mitral valve repair

open access: yesFrontiers in Cardiovascular Medicine, 2023
BackgroundAtrial fibrillation (AF) is the most common concomitant disease in patients undergoing transcatheter edge-to-edge repair (TEER) for mitral regurgitation (MR) and detrimentally affects their outcome.
Felix Ausbuettel   +16 more
doaj   +1 more source

Home - About - Disclaimer - Privacy