Temporary overvoltage capability of surge arresters for 1000 kV power systems
AbstractInsulation level (LIWV 2250 kV) of 1000 kV gas insulated switchgear will be adopted by installing high performance 1000 kV surge arresters. But when temporary overvoltage (TOV) is generated in power systems at line faults and load rejection including Ferranti effects, high performance surge arresters flow discharge current according to the ...
Shingo Shirakawa
exaly +3 more sources
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Study of different techniques to mitigate temporary overvoltage in photovoltaic system
Materials Today: Proceedings, 2022Abstract This paper investigates the cause of temporary overvoltage in PV system and different ways to mitigate them. Temporary overvoltage is an undesired phenomenon in distributed generation system which needs to be eliminated using different transformer configuration and grounding banks.
Manam Ravindra
exaly +2 more sources
A study of temporary overvoltage at HVDC rectifier stations
This paper presents a study of Temporary Overvoltage (TOV) on the Manitoba Hydro rectifier system under the proposed development of a new HVDC link and generations. The TOV assessment is based on a full load rejection of three Bipoles, which should result in the highest temporary fundamental frequency overvoltage.
Chenghong Zhou, Pei Wang
openaire +2 more sources
Temporary Overvoltage (TOV) Test Values for SPDs in Japan
In IEC 61643-11:2011 [1], the temporary overvoltage (TOV) test method and test values to confirm the safety of the SPD in TOV are specified. However, this TOV test values is based on the three phase 4 wire Y connection 230/400V system defined by the IEC 60364series, which are different from the actual situation in Japan.TOV caused by faults in low ...
Kensuke Kaito +2 more
openaire +2 more sources
Temporary Overvoltage and GPR Characteristics of Distribution Feeders With Multigrounded Neutral
IEEE Transactions on Power Delivery, 2010Three-phase four-wire multigrounded neutral (MGN) is the preferred distribution line configuration in North America. Its performance characteristics, such as temporary overvoltage (voltage swell) and ground potential rise (GPR), are difficult to understand and assess due to the presence of a neutral conductor and the conductor's multiple grounding ...
Yunfei Wang, Wilsun Xu
exaly +2 more sources
Investigation and mitigation of temporary overvoltage caused by harmonic filters in an oil refinery
Harmonic distortion caused by non-linear loads pose a threat to power quality that may result in failures or damage to various components of the electrical system. In this work the harmonic distortion in an oil refinery is investigated using the ATP/EMTP software. Harmonic filters are used to reduce harmonic distortion by diverting harmonic currents in
Prenushka Ayar +2 more
openaire +2 more sources
This paper presents a comprehensive analysis of the impact of Distributed Generator Interface Transformer (DGIT) configuration on Temporary Over Voltage (TOV) on the healthy phases in a distribution feeder during an unsymmetrical fault. Three common types of transformer configurations are investigated both analytically and using EMTDC/PSCAD ...
Pouyan Saifi +3 more
openaire +2 more sources
In general, a temporary overvoltage (TOV) on the healthy phases occurs because of the neutral-shift phenomenon during a single line-to-ground (SLG) fault.
Namhun Cho +2 more
exaly +2 more sources
Temporary Overvoltage Mechanism Analysis of Renewable Energy
2024 IEEE 2nd International Conference on Power Science and Technology (ICPST)Shiyun Xu
exaly +2 more sources