Results 11 to 20 of about 4,856,935 (296)
An instrumented microindentation testing device
An experimental device for microindentation testing has been designed and constructed. The device can be used together with standard testing machines and allows for continuous recording of indentation loads up to approximately 500 N and indentation ...
Larsson, Per-Lennart, +2 more
core +8 more sources
FATIGUE DEVICE FOR TESTING ANKLE JOINT ENDOPROSTHESES [PDF]
The paper proposes a model of a fatigue device for testing dedicated to ankle prostheses. The concept of the testing device relies on two aspects: almost any type of ankle prosthesis can be tested on it and it has to work on INSTRON axial-torsion testing
Cristian TOADER-PASTI +2 more
doaj +2 more sources
Nickel nanoparticles (NiNPs) have wide applications in industry and biomedicine due to their unique characteristics. The liver is the major organ responsible for nutrient metabolism, exogenous substance detoxification and biotransformation of medicines ...
Shuang Zhou +9 more
doaj +1 more source
This paper proposes a combined strategy of using paper-based competitive immunochromatography and a near field communication (NFC) tag for wireless cotinine determination.
Nutcha Larpant +3 more
doaj +1 more source
Portable Heat Pump Testing Device [PDF]
The aim of this paper is to present the design and working principle of a portable testing device for heat pumps in the energy recirculation system. The presented test stand can be used for any refrigerating/reverse flow cycle device to calculate the ...
Kłosowiak, R. +5 more
core +1 more source
Endoscope reprocessing: Retrospective analysis of 90,311 samples
Background and study aims The contamination level of ready-to-use endoscopes published in the literature varies from 0.4 % to 49.0 %. Unfortunately, the comparison and the interpretation of these results are quite impossible, given the limited number of ...
Lionel Pineau
doaj +1 more source
Advances in the Tribological Research of Ceramic-on-Ceramic Artificial Joints
Ceramic-on-ceramic (CoC) bearings are widely used in total hip arthroplasty due to their extremely low wear rate, excellent chemical stability, and good biocompatibility.
Menglin Zhou +6 more
doaj +1 more source
Analysis and Mitigation Strategies for Failure in Orthopedic Surgical Robots
With the breakthroughs in artificial intelligence, orthopedic surgical robots have rapidly advanced, presenting good prospects for their applications in the medical field.
LIU Xun +4 more
doaj +1 more source
In magnetic resonance examination, the interaction between implants and the radio frequency (RF) fields induces heating in human tissue and may cause tissue damage.
Yonghua LI +8 more
doaj +1 more source
Investigation of Coupling Effect for Adjacent Orthopedic Implants on MRI Radio-Frequency Heating
This paper investigates the mechanism of radio-frequency (RF) heating that occurs when two adjacent orthopedic implants are present together under magnetic resonance imaging (MRI) at 1.5 Tesla and 3.0 Tesla.
Ran GUO +5 more
doaj +1 more source