FATIGUE DEVICE FOR TESTING ANKLE JOINT ENDOPROSTHESES [PDF]
The paper proposes a model of a fatigue device for testing dedicated to ankle prostheses. The concept of the testing device relies on two aspects: almost any type of ankle prosthesis can be tested on it and it has to work on INSTRON axial-torsion testing
Cristian TOADER-PASTI +2 more
doaj +2 more sources
The role of the user within the medical device design and development process: Medical device manufacturers' perspectives [PDF]
Copyright @ 2011 Money et al.Background: Academic literature and international standards bodies suggest that user involvement, via the incorporation of human factors engineering methods within the medical device design and development (MDDD) process ...
Jennifer L Martin +23 more
core +1 more source
This guideline is applicable to the static calibration and verification of torsion testing machines using a procedure based on the calibration of materials testing machines according to DIN EN ISO 7500-1.
DKD Technical Committee Materials Testing Machines
core +1 more source
Radiated Immunity Testing of a Device with an External Wire: Repeatibility of Reverberation Chamber Results and Correlation with Anechoic Chamber Results [PDF]
We present the experimental radiated immunity results of an electronic device with an external wire obtained in reverberation and anechoic chambers. Repeatability and reproducibility of reverberation chamber measurements are investigated by repeating the
Berat, V. +6 more
core +1 more source
Robust Inference for One-Shot Device Testing Data Under Weibull Lifetime Model
Classical inferential methods for one-shot device testing data from an accelerated life-test are based on maximum likelihood estimators (MLEs) of model parameters. However, the lack of robustness of MLE is well-known.
Balakrishnan, Narayanaswamy +3 more
core +1 more source
Frequent viral load testing is necessary during analytical treatment interruptions (ATIs) in HIV cure-directed clinical trials, though such may be burdensome and inconvenient to trial participants. We implemented a national, cross-sectional survey in the
Peterson, Beth +53 more
core +1 more source
Portable Heat Pump Testing Device
The aim of this paper is to present the design and working principle of a portable testing device for heat pumps in the energy recirculation system. The presented test stand can be used for any refrigerating/reverse flow cycle device to calculate the ...
Kłosowiak, R. +5 more
core +1 more source
Unraveling the genetic traits and functional diversity of the pan-genome in Pantoea dispersa
Background Medical devices are crucial in modern healthcare, but commonly used clinical tools such as cotton swabs can be easily contaminated by microorganisms (such as Pantoea), becoming vectors for pathogens and leading to patient infections or more ...
Shiyao He +7 more
doaj +1 more source
Development of a Lumped Parameter Model of Human Whole Body Circulatory Loop
The simulation of human cardiovascular dynamics is essential for understanding organ pathology and advancing cardiovascular assistive devices. However, a notable gap remains in defining comprehensive hemodynamic parameters for testing ventricular assist ...
Xun Liu +7 more
doaj +1 more source
In order to evaluate the reliability of the ID ICP-MS method for the measurement of magnesium, zinc, and copper in human serum, we investigated the traceability, precision, trueness, and uncertainty of the method.
Jian Yang, Lixia Chi, Shengmin Li
doaj +1 more source