Pediatric Digital Artery Pseudoaneurysm From Repetitive Compression While Gripping Toys. [PDF]
Uno K +5 more
europepmc +1 more source
Bamboo Medical Application: A State‐of‐the‐Art Review
This review presents a structured classification of bamboo's current use in healthcare. It organizes applications into medical textiles and medical devices, with further divisions based on function and level of invasiveness. It also examines material utilization based on bamboo's structural role, highlighting how it supports both protective and ...
Haymanot Beza Lamesgin +3 more
wiley +1 more source
On the origin of acoustic emission in the stress-induced martensite regime of shape memory alloys. [PDF]
Lauhoff C +10 more
europepmc +1 more source
Metallic microparticles dispersed in liquid metal interconnects mitigate electromigration‐induced failure by reconfiguring internal current density distributions. These fillers facilitate the growth of a robust, protective gallium oxide shell at elevated temperatures, shifting the failure threshold toward a thermal limit.
Ethan J. Krings +6 more
wiley +1 more source
Cervical flexion-induced myelopathy (Hirayama disease): A radiology case report. [PDF]
Ulaganathan B +3 more
europepmc +1 more source
Flexible silicon carbide (SiC) microelectrode arrays enable high‐fidelity, multichannel cell extracellular recording and precise localized ablation. SiC has been extensively evaluated to persist long‐term in chronic physiological conditions while remaining robust, with excellent electrical and electrochemical stability.
Minh Anh Huynh +4 more
wiley +1 more source
Micromachined Double‐Membrane Mechanically Tunable Metamaterial for Thermal Infrared Filtering
Herein, a mechanically tunable double‐layer plasmonic metamaterial leveraging the extraordinary optical transmission effect observed in subwavelength arrays of openings within thin metal layers is presented. The concept is experimentally validated by integrating the proposed metamaterial structure into an electrostatic parallel‐plate actuator to create
Oleg Bannik +7 more
wiley +1 more source
Arterial thoracic outlet syndrome due to a first-rib anomaly causing brachial artery embolic occlusion: a case report. [PDF]
Yan N +10 more
europepmc +1 more source
A soft robotic simulator is developed to replicate the digital removal of feces (DRF), a sensitive yet essential nursing procedure. Integrating soft actuators, sensors, and a realistic rectal model, the simulator balances functional fidelity with perceptual realism. Engineering evaluations and nurse feedback confirm its potential to enhance training in
Shoko Miyagawa +10 more
wiley +1 more source
Effect of different durations of compression therapy on quality of life and recurrence after thermal ablation for varicose veins: a protocol for a prospective, multicenter, randomized controlled trial. [PDF]
Yang L +6 more
europepmc +1 more source

