Results 31 to 40 of about 1,014 (166)
Evaluation of Electrical Harmonics in Building Installations
This study aims to determine the level of harmonics, and conduct harmonic analysis on the electrical system in the new Building of the Information Technology Department of Samarinda State Polytechnic.
Rizky Aprylianto Susilo +5 more
doaj +1 more source
Análisis del efecto de la variación de parámetros del controlador PWM y de la carga en el THDi de una microred basada en generación fotovoltaica [PDF]
En este trabajo se realizó un análisis del efecto de la variación de parámetros del controlador PWM y de la carga en el THDi (distorsión armónica total en corriente) de un sistema fotovoltaico aislado.
Lemus Pérez, Darío Hernando
core
ABSTRAK Penelitian ini membahas Active Front End Converter (AFE) tiga-fasa tiga-kaki menggunakan kendali Model Predictive Control (MPC) pada pensakelaran converter yang dapat mengurangi nilai harmonisa dan memperbaiki faktor daya pada jaringan.
ORYZA SATIVA, ASEP ANDANG, ABDUL CHOBIR
doaj +1 more source
PPV‐M, an amorphous electron transporting polymer with a high Tg of 118°C, suppresses thermally induced molecular diffusion in organic solar cells. Unlike crystalline PDINN (Tg = 61°C) with a T80 of only 8 h, PPV‐M maintains efficient electron extraction and extends T80 to 637 h, representing an 80‐fold enhancement in thermal stability.
Youngwan Lee +12 more
wiley +1 more source
Effect of Non-Linear Load Harmonics on Single phase Transformer Losses and Design Active Filter [PDF]
As a result of the negative effects unshaped on some of the components in power systems such as the transformers, a great concern was shown to treatment this phenomenon so we rise in this search by designing a suitable active filter with two strategies ...
Zainab Nadhem Abbas Al-Mousaoy
doaj +1 more source
The benefits of total harmonic distortion of currents (THDi) reduction in cables of low voltage power distribution system / Mohammad Nizam Ibrahim, Irni Hamiza Hamzah and Linda Mohd Kasim [PDF]
Harmonic currents are generated by single and three-phase non-linear electronic loads. The usage of non-linear loads increasing rapidly and the quantity of these types of loads are dominant of the power system loads since its have higher efficiency and ...
Mohd Kasim, Linda +2 more
core
An optimal filter design method was developed to address system uncertainties in distribution networks. Harmonic modal analysis was conducted across multiple operating scenarios to account for variations caused by component parameter deviations, intermittent renewable generation and load fluctuations.
Nien‐Che Yang, Kai‐You Lai
wiley +1 more source
AC (Air Conditioner), TV, lamp, LCD and others are categorized as nonlinear load generating harmonics. The high content of harmonics has a negative impact on the quality of electrical power.
I. G. N. Janardana +2 more
doaj +1 more source
Properties of active rectifier with LCL filter in the selection process of the weighting factors in finite control set-MPC [PDF]
One of the main problems of multivariable cost functions in model predictive control is the choice of weighting factors. Two finite control set model predictive control algorithms, applied to the three-phase active rectifier with an LCL filter, are ...
P. Falkowski +3 more
doaj +1 more source
This article presents a dual‐source novel nine‐level inverter (DSN2LI) featuring minimal devices. Utilizing eight switches, which include 2 bidirectional switching devices and 2 uneven dc links, the proposed DSN2LI generates nine levels. The DSN2LI employs the utilization of trinary geometric DC links.
Arun Vijayakumar +3 more
wiley +1 more source