Results 11 to 20 of about 290,321 (263)
Fractures are developed in carbonate rock areas, and the fracture water flow significantly influences the heat exchange between buried pipes and the rock mass by induing heat convection, providing the carbonate rock area a strong heat exchange capacity ...
Lin Wang +4 more
doaj +1 more source
The use of renewable energies, and of geothermal energy in particular, is increasingly being applied in Germany and Europe for the development of new residential districts.
Oliver Suft, David Bertermann
doaj +1 more source
The performance of ground heat exchanger systems depends on the knowledge of the thermal parameters of the ground, such as thermal conductivity, capacity, and diffusivity.
Alessandro Franco, Paolo Conti
doaj +1 more source
Comprehensive application of hydrogeological survey and in-situ thermal response test
Thermal properties of rock-soil are of great importance for the design of borehole heat exchangers (BHEs). In the process of testing thermal properties of rock-soil through an in-situ thermal response test (TRT), groundwater seepage directly affects the ...
Wei Song +4 more
doaj +1 more source
To design an efficient ground source heat pump (GSHP) system, it is important to accurately measure the thermophysical parameters of the geotechnical layer.
Yongjie Ma +5 more
doaj +1 more source
The recognition of geological and thermal conditions of the rock mass in the case of designing a vertical borehole heat exchanger as the ground source for heat pump installations is a key issue affecting the efficiency of the heating/cooling system ...
Kaczmarczyk Michał +3 more
doaj +1 more source
Heat advection caused by groundwater flow can potentially improve the performance of a borehole heat exchanger. However, the required flow velocity is not achieved under most natural conditions. This study focuses on artificial groundwater flow generated
Yoshitaka Sakata +3 more
doaj +1 more source
A ground source heat pump system is a highly efficient renewable heating, cooling, and ventilation system that utilizes the ground as a heat source or sink via ground heat exchangers.
He Qi +6 more
doaj +1 more source
The impact of different parameter estimation results on the design length of a borehole heat exchanger has received very little attention. This paper provides an in-depth investigation of this problem, together with a full presentation of six data ...
Xuedan Zhang +3 more
doaj +1 more source
In this study, a mobile measuring device was developed and a thermal response test that applied a standing column well-type heat exchanger was conducted to obtain design parameters from field measurements.
Jangyoul You, Changhee Lee
doaj +1 more source