Results 111 to 120 of about 2,572 (229)
Pressure retarded osmosis thermosyphon
The basis of a novel method for passive solar water heating homologous to the thermosyphon but driven by induced salinity which circulates a fluid without the necessity of a mechanical pump and with inverse natural convection is outlined.
Heras Jiménez, Salvador Augusto de las +1 more
core
Two-phase thermosyphon loop for cooling outdoor telecommunication equipments
International audienceDevelopment of high bit rate services requires extension of the telecom network and then the power inside the France Telecom telecommunication outdoor cabinets.
Le Masson, Stéphane +3 more
core +1 more source
Fabrication and visualization of a loop thermosyphon
碩士本文為研製與測試可視化之迴路式虹吸熱管,其蒸發器內部為直徑35mm、長19mm,汽相流道外徑9mm、液相流道外徑6mm,管壁厚度各為1.5mm,冷凝器管路內直徑6mm、長81mm,加熱面積為31mm x 31mm。 迴路式虹吸熱管於內部壓力7 Torr(mmHg)下充填20%之去離子水,銅粉燒結毛細結構之直徑為35mm並製作成三種不同之厚度分別為0.4mm、0.7mm、1.0mm,銅粉平均粒徑與孔隙率分別為100μm及51%。輸入功率逐步由18W增加至236W ...
黃俊賢; Huang, Chun-hsien
core
Asymptotic Behaviour of a Thermosyphon model with binary fluids [PDF]
En este trabajo se generalizan algunos resultados del comportamiento de un termosifón con un fluido de una sola componente a un fluido binario.The aim of this work is the generalization for a thermosyphon model where on be considered a binary fluid, of ...
Jiménez Casas, Ángela
core
An Investigation into the Performance of a Thermosyphon Heat Exchanger
In this investigation, work was carried out to evaluate the thermal performance of Thermosyphon and its use as a heat exchanger in air condition test rig for heat recovery.
Singh, Gurtej
core
A Design for Loop Thermosyphon Including Effect of Non-Condensable Gas
We have developed a loop thermosyphon for cooling electronics devices. Its cooling performance changes with the ambient temperature and amount of input heating. Especially it deteriorates with non-condensable gas (NCG) increase.
Akio Idei +4 more
core +1 more source
THERMOSYPHON IN BUILDINGS: A SOLUTION FOR THERMAL BRIDGING
Thermal bridging is a problem that arises from using a thermosyphon. It is used as a passive part of the building envelope in south facing walls. A solution is proposed and investigated in this paper.
S Lefrene, Alan S Fung, M Ebrahim Poulad
core
Experimental study on the temperature management behaviours of a controllable loop thermosyphon
The loop thermosyphon with active heat transfer control capability is a promising solution for the temperature management of the fresh food compartment of cool-storage refrigerators or other precise temperature control devices.
Pei G. +5 more
core +1 more source
Optimal viscosity modelling of 10W40 oil-based MWCNT (40%)-TiO2 (60%) nanofluid using Response Surface Methodology (RSM). [PDF]
Hemmat Esfe M, Motallebi SM, Toghraie D.
europepmc +1 more source
Titanium-Water Thermosyphon Gamma Radiation Exposure and Results
Titanium-water thermosyphons are being considered for use in heat rejection systems for fission power systems. Their proximity to the nuclear reactor will result in some gamma irradiation.
Jaworske, Donald, A. +2 more
core +1 more source