Results 91 to 100 of about 2,572 (229)
Experimental Investigation of the Two-Phase Closed Thermosyphon Thermal Performance
In this study, fabrication of the two-phase closed thermosyphon with annulations grooved wick and forced convection air cooled by inside thermosyphon.
康尚文; 蔡孟昌; 林維忠; 盧玟銨 +1 more
core
Experimental investigation of straight shape thermosyphon filled with R410A refrigerant [PDF]
The thermal performances of a R410A filled thermosyphon subjected to low heat flux from 1882 W/m2 to 4423 W/m2 and evaporator wall temperatures between 20 °C and 40 °C with fill ratios 0.75 and 1.00 and at different inclinations from 45° to 90° were ...
Uddin, Mohammad Faisal +2 more
core
Wall shape optimization for a thermosyphon loop featuring corrugated pipes [PDF]
In the present paper we address the problem of optimal wall-shape design of a single phase laminar thermosyphon loop. The model takes the buoyancy forces into account via the Boussinesq approximation.
Thije Boonkkamp, ten, J.H.M. +12 more
core +1 more source
Design and Development of an Energy-Efficient Suki Sauce Stirrer: A Novel Concept Study [PDF]
This study presents the design and evaluation of an energy-efficient sukiyaki sauce stirrer incorporating thermosyphon technology to reduce both heating time and fuel consumption.
Booddachan Khridsadakhon +5 more
doaj +1 more source
Devices called reverse thermosyphon enable passive heat transfer when the heat source is above the place of its receipt. This is often the case in solar installations for the preparation of hot water.
Duda Michal +2 more
doaj +1 more source
Design of a chocolate tempering machine with thermosyphon installation – a new concept study [PDF]
This research presents a case study of applying a thermosyphon for energy conservation in a chocolate temper process. The use of the thermosyphon, made of 304 stainless steel, aimed to achieve a uniform temperature distribution, control temperature and ...
Parametthanuwat Thanya +4 more
doaj +1 more source
Polymer and Composite Materials in Two-Phase Passive Thermal Management Systems: A Review. [PDF]
Alqahtani AA, Bertola V.
europepmc +1 more source
Experimental Investigation of Airfoil Thermosyphons [PDF]
Both cooling fins and closed two-phase thermosyphons are widely used in many fields for passive thermal management. Assuming a favorable gravitational field, the development of a cooling fin thermosyphon device could enhance the heat transfer capabilities of a cooling fin alone.
openaire +1 more source
Field Experiment of Top-Heat Thermosyphon
Three types of thermosyphon were tested. Type-1 has a horizontal condenser with a 536ml volume buffer chamber. The vertical heat transfer height was 3m. In type-2, condenser and connecting pipe were tilted by 10° to the ground with 3776ml buffer chamber.
Naoto Hagino +2 more
core +1 more source
Use of LHP for cooling power electronic components
The paper deals with use of cooling equipment build on basis two phase thermosyphon loop. This device belongs to a group of loop heat pipe (LHP).
Kolková Z. +3 more
doaj +1 more source