Results 81 to 90 of about 3,331 (222)
Study on dry-out occurrence in inclined loop thermosyphon for CPU cooling
A loop thermosyphon is known to have a higher heat transfer performance without a pump. In addition, there is demand for the reduction of the electricity needed for the fan used to cool the CPUs in a rack mount server.
Hiroyuki TOYODA +4 more
doaj +1 more source
Wind-driven device for cooling permafrost. [PDF]
Qin Y, Wang T, Yuan W.
europepmc +1 more source
Análise de um circuito de termossifão bifásico [PDF]
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Mecânica.A crise energética que o país atravessa estimula o desenvolvimento de pesquisas visando fontes alternativas e a ...
Nisgoski, Andre Roberto
core
International audienceIn this paper, experimental investigations of a two-phase thermosyphon loop are presented in order to keep telecommunication equipments temperature below 55°C.
Mecheri, B. +3 more
core +2 more sources
Experimental Study of the Thermal Characteristics for a Thermosyphon Pipe with Finned Condenser
The thermosyphon pipes are two-phase heat transfer devices with extremely high effective thermal conductivity. In this work, the thermal characteristics of a thermosyphon pipe with finned condenser (free convection condenser) is studied experimentally ...
Obaid T. Fadhil +2 more
doaj
The gas industry relies on indirect heating to prevent gas from freezing when it is transferred from high-pressure networks to lower pressure distribution systems.
Stefan Romocki +4 more
doaj +1 more source
Influence of cellulose nanofiber fluid on flow instability and heat transfer of two-phase closed thermosyphon. [PDF]
Lee CH, Seo SW, Park DK, Lee KY.
europepmc +1 more source
Numerical simulation of heat and mass transfer in a closed two – phase geothermal thermosyphon
Mathematical model of the heat and mass transfer process in a two-phase thermosyphon with allowance for the coolant phase transformations is presented in this study. The formulated boundary-value problem was solved by the finite differences method.
Valieva Lily, Nee Alexander
doaj +1 more source
Information and communication technology (ICT) cooling devices increasingly need to be able to be installed in high-density packaged equipments, especially these exposed to high-temperature environments such as 1U-height servers and packet transport ...
Takayuki FUJIMOTO +4 more
doaj +1 more source
Polymer and Composite Materials in Two-Phase Passive Thermal Management Systems: A Review. [PDF]
Alqahtani AA, Bertola V.
europepmc +1 more source