Three flat‐plate collectors with spiral and square coiled riser tubes were tested and it was found that the spiral type provides the best results with a thermal efficiency of 66.98% for a mass flow rate of 0.4 kg/min. Riser tube geometry is a key factor in optimizing flat‐plate collector output.
Sakhail Islam Biaz +4 more
wiley +1 more source
ABSTRACT This study presents the design and construction of an experimental system for evaluating the thermal performance of heat pipes, using sintered‐wick heat pipes charged with CuO nanofluids. The device used in this study is a sintered‐wick heat pipe, in which the liquid return is driven by capillary forces within the porous wick structure.
Dawei Yan +7 more
wiley +1 more source
Análise de termossifões que operam com mercúrio em altas temperaturas: [tese] [PDF]
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Mecânica.Os termossifões são dispositivos de condutividade térmica muito elevada, sendo capazes de transportar grandes quantidades de ...
Cunha, André Felippe Vieira da
core
Fluids subject to thermal gradients produce complex behaviors that arise from the competition with gravitational effects. Although such sort of systems have been widely studied in the literature for simple (Newtonian) fluids, the behavior of viscoelastic
Justine Yasappan +2 more
doaj +1 more source
Communication: An approach for a holistic evaluation of distillation processes with mechanical vapor recompression combining an initial energy potential analysis, shortcut methods for the compressor and reboiler design, and the determination of economic and ecological performance parameters is presented.
Katharina Jasch +4 more
wiley +1 more source
Role of graphene nanofluids on heat transfer enhancement in thermosyphon
The thermophysical properties of graphene nanofluids in thermosyphon have been studied at different power inputs, temperatures and angles of inclination.
Sidhartha Das +3 more
doaj +1 more source
Extended graphite–enhanced TBAB PCM integrated with an evacuated tube solar collector improves thermal conductivity, heat storage, and efficiency, achieving higher operating temperatures, rapid heat absorption, reduced CO2 emissions, significant energy savings, and short payback for sustainable low‐temperature solar heating.
T. Sathish, A. Johnson Santhosh
wiley +1 more source
This review presents a comparative analysis of experimental studies aimed at improving the thermal efficiency of solar water heating (SWH) systems. Various enhancement techniques, including nanofluids, phase change materials, optimized collector designs, and hybrid photovoltaic–thermal systems, are evaluated based on their impact on system performance ...
Oluwaseyi O. Alabi +2 more
wiley +1 more source
The investigation into a full-scale 27 m high, by 6 m wide, thermosyphon loop. The simulation model is based on a one-dimensional axially-symmetrical control volume approach, where the loop is divided into a series of discreet control volumes.
R. Swart, R.T. Dobson
doaj +1 more source
In present paper the influence of the boiling surface treatment types of thermosyphon evaporator on the heat transfer coefficient was studied. An experimental setup «Loop thermosyphon with replacing lower part of the evaporator» has been developed and ...
M. A. Kuzmich, A. A. Artsiukh
doaj +1 more source