Results 21 to 30 of about 4,060 (218)
Majorana Thermosyphon Prototype Experimental Results [PDF]
Objective The Majorana demonstrator will operate at liquid Nitrogen temperatures to ensure optimal spectrometric performance of its High Purity Germanium (HPGe) detector modules.
Estanislao Aguayo Navarrete +5 more
core +1 more source
Energy-saving Potential Study on Telecommunication Base Station Free Cooling With a Thermosyphon Heat Exchanger in China [PDF]
The energy consumption of air conditioning for a telecommunication base station (TBS) in China can be significantly decreased when an air to air thermosyphon heat exchanger is used for free cooling in low atmosphere temperature days.
Zhou, Feng +3 more
core +1 more source
This paper presents the effect of filling ratio on thermal performance;of a loop thermosyphon. The experimental setup consists of an evaporator, a condenser, a riser and a downcomer.
Samah Ihsan Adnan +2 more
doaj +3 more sources
Majorana Thermosyphon Prototype Experimental Setup [PDF]
This report presents the experimental setup of Pacific Northwest National Laboratory’s MAJORANA DEMONSTRATOR thermosyphon prototype cooling system. A nitrogen thermosyphon prototype of such a system has been built and tested at PNNL.
Anthony D. Guzman +5 more
core +1 more source
Numerical analysis of thermal conditions of a two-phase closed thermosyphon using the software package ANSYS FLUENT has been carried out. Time dependence of temperature of heat source surface, which characterize the efficiency of thermosyphon at critical
Krasnoshlykov Alexander
doaj +1 more source
Visualization Study on Thermo-Hydrodynamic Behaviors of a Flat Two-Phase Thermosyphon
The coupled effect of boiling and condensation inside a flat two-phase thermosyphon has a non-negligible influence on the two-phase fluid flow behavior and heat transfer process.
Chao Wang +4 more
doaj +1 more source
Numerical Study on the Transient Thermal Performance of a Two-Phase Closed Thermosyphon
The transient thermal performance of phase change and heat and mass transfer in a two-phase closed thermosyphon are studied with computational fluid dynamics (CFD). A CFD model based on the volume of fluid technique is built. Deionized water is specified
Zhongchao Zhao +4 more
doaj +1 more source
Experimental modelling of evaporation and boiling processes in a two-phase thermosyphon
A model of a closed two-phase thermosyphon was developed to study thermo-physical processes in a thermosyphon thermal condition systems of energy-saturated equipment.
Ponomarev Konstantin +3 more
doaj +1 more source
In article, presents the results of experimental determination of temperature distributions in characteristic sections of the working zone of a closed two-phase thermosyphon.
G. V. Kuznetsov, A. E. Nurpeiis
doaj +1 more source
Numerical modelling of the operation of a two-phase thermosyphon [PDF]
In the recent years, the interest towards the application of two-phase thermosyphons as an element of heat recovery systems has significantly increased.
Ahmed Ahmedov (4802859) +4 more
core +3 more sources