Results 11 to 20 of about 2,572 (229)
An Assessment of Momentum Models for Two-phase Thermosyphon Loop
Two-phase thermosyphon heat exchangers are widely used in different industry fields. The fluid flow characteristic is very important for the design of thermosyphon.
Zhang Penglei +4 more
doaj +2 more sources
Experimental and analytical performance investigation of air to air two phase closed thermosyphon based heat exchangers [PDF]
In recent years, the use of wickless heat pipes (thermosyphons) in heat exchangers has been on the rise, particularly in gas to gas heat recovery applications due to their reliability and the level of contingency they offer compared to conventional heat ...
Sayegh, MA +4 more
core +1 more source
Effects of inclination angles on heat transfer performance of a loop thermosyphon for CPU cooling
A loop thermosyphon is known that it has higher heat transfer performance without a pump. Thus, we have applied new loop thermosyphon to cool CPUs of a rack mount server.
Hiroyuki TOYODA +3 more
doaj +1 more source
A three-dimensional steady state CFD model was developed in ANSYS-Fluent CFD solver to analyze heat transfer capability as well as the wall temperature distribution along the lateral walls of thermosyphon.
Linto P Anto, James Varghese
doaj +1 more source
The main categories of solar water heating systems (SWHSs) are the thermosyphon and the forced circulation (FC). This paper presents an experiment carried out with the aim to compare the energy performance of the FC with a thermosyphon SHWS.
Evangelos I. Sakellariou +3 more
doaj +1 more source
Objective. The objective of the study is to develop a design model of the electronic equipment cooling system based on the combined use of high-current thermoelectric semiconductor batteries of layered design and an evaporative-condensing thermal ...
A. B. Sulin +3 more
doaj +1 more source
Energy Sources and Thermal Management Technologies for Electric Vehicle Batteries: A Technical Review. [PDF]
Overview of Battery Thermal Management System (BTMS) methods, including air, liquid, cold plate, and hybrid cooling strategies—highlighting direct/indirect liquid techniques and hybrid integrations like PCM, refrigerant, and heat pipe systems. Abstract Efficient thermal management of high‐power lithium‐ion batteries (LiBs) is critical for ensuring ...
Rahman MA +6 more
europepmc +2 more sources
Experimental Research of Thermophysical Processes in A Closed Two-Phase Thermosyphon
The temperature distribution in a thermosyphon was studied experimentally. To conduct the research, a closed two-phase thermosyphon was developed, which differs from the known by simple construction.
Feoktistov D.V. +2 more
doaj +1 more source
Thermal Performance of a Loop Thermosyphon [PDF]
100學年度研究獎補助論文Experimental investigations were performed on a loop thermosyphon, consisting of a condensation section and an evaporation section. The evaporator chamber used in this study has an inside diameter of 25 mmand a height of 25 mm.
Kang, Shung-wen; Tsai, Meng-chang; Hsieh, Chih-sheng; Chen, Jian-you +1 more
core +1 more source
Thermosyphon by refrigerant self‐excited oscillation
In the compact closed two-phase thermosyphon, boiling area is adjacent to condensation area and condensation area is provided with innerfin uniquely against conventional thermosyphons. We clalified that the combination of condensation and self-excited oscillation convection resulted in good heat release.
OSAKABE, Hiroyuki +3 more
openaire +2 more sources