Results 11 to 20 of about 4,060 (218)

Experimental study of thermosyphon operation when cooling the condensation part by drop irrigation [PDF]

open access: yesMATEC Web of Conferences, 2017
The influence of drop irrigation of the condensation part on the thermosyphon operational mode was studied experimentally. The temperature and pressure fall was found in the internal space of the upper chamber after applying the liquid on the upper wall ...
Ponomarev Konstantin O.   +2 more
doaj   +3 more sources

Experimental Research of Thermophysical Processes in A Closed Two-Phase Thermosyphon [PDF]

open access: yesMATEC Web of Conferences, 2016
The temperature distribution in a thermosyphon was studied experimentally. To conduct the research, a closed two-phase thermosyphon was developed, which differs from the known by simple construction.
Feoktistov D.V.   +2 more
doaj   +3 more sources

An Assessment of Momentum Models for Two-phase Thermosyphon Loop

open access: yesZhileng xuebao, 2013
Two-phase thermosyphon heat exchangers are widely used in different industry fields. The fluid flow characteristic is very important for the design of thermosyphon.
Zhang Penglei   +4 more
doaj   +2 more sources

Design of a chocolate tempering machine with thermosyphon installation – a new concept study [PDF]

open access: yesE3S Web of Conferences
This research presents a case study of applying a thermosyphon for energy conservation in a chocolate temper process. The use of the thermosyphon, made of 304 stainless steel, aimed to achieve a uniform temperature distribution, control temperature and ...
Parametthanuwat Thanya   +4 more
doaj   +4 more sources

Mathematical Modeling of Hydrodynamic and Heat Transfer in a Two-Phase Thermosyphon [PDF]

open access: yesEPJ Web of Conferences, 2016
This paper presents the solution results of conjugate forced convection boundary value problem in a typical rectangular cross-section thermosyphon. The influence of convective heat exchange at the external top horizontal boundary on the heat transfer ...
Nee Alexander, Nurpeiis Atlant
doaj   +2 more sources

Experimental and analytical performance investigation of air to air two phase closed thermosyphon based heat exchangers [PDF]

open access: yes, 2014
In recent years, the use of wickless heat pipes (thermosyphons) in heat exchangers has been on the rise, particularly in gas to gas heat recovery applications due to their reliability and the level of contingency they offer compared to conventional heat ...
Sayegh, MA   +4 more
core   +1 more source

Experimental investigation of small diameter two-phase closed thermosyphons charged with water, FC-84, FC-77 and FC-3283 [PDF]

open access: yes, 2009
Copyright © 2009 Elsevier Ltd. All rights reserved.An experimental investigation of the performance of thermosyphons charged with water as well as the dielectric heat transfer liquids FC-84, FC-77 and FC-3283 has been carried out. The copper thermosyphon
Robinson, AJ   +3 more
core   +1 more source

Modeling the Transient Response of a Thermosyphon [PDF]

open access: yes41st Aerospace Sciences Meeting and Exhibit, 2003
Thermosyphon transient operation was numerically modeled. The numerical model presented in this work overcame the limitations of previous studies by including transient conduction in the vessel wall, shear stress between the rising vapor and the falling
J. Storey, W. Bowman
openaire   +3 more sources

Thermosyphon by refrigerant self‐excited oscillation

open access: yesHeat Transfer—Asian Research, 1998
In the compact closed two-phase thermosyphon, boiling area is adjacent to condensation area and condensation area is provided with innerfin uniquely against conventional thermosyphons. We clalified that the combination of condensation and self-excited oscillation convection resulted in good heat release.
OSAKABE, Hiroyuki   +3 more
openaire   +2 more sources

Experimental study of inclination angle on an internally two-phase closed thermosyphon thermal behaviour [PDF]

open access: yesThe Egyptian International Journal of Engineering Sciences and Technology, 2023
This work studies the inclination angle effect on the two-phase closed thermosyphon (TPCT) with semicylindrical condenser internal fins. The finned thermosyphon thermal performance is studied at two different inclination angles 30o and 60o.
ahmed elshabrawy   +4 more
doaj   +1 more source