Results 51 to 60 of about 5,426 (206)

Ferromagnetically Shielded Fault Current Limiter (FS‐FCL) Evaluation in Power Line

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
This study introduces a new ferromagnetically shielded FS‐FCL design and its control strategy for limiting and interrupting fault currents. The fully shielded core structure enhances inductance and prevents saturation, enabling an immediate fault response without causing voltage drop during normal conditions.
Kamran Ghorbanyan, Selim Acar
wiley   +1 more source

Generation Algorithms for Thévenin and Norton Equivalent Circuits

open access: yesEnergies
The growing complexity of electrical systems requires advanced analysis tools to optimize the design time and resources. While many circuit simulators exist, they often lack the flexibility needed for real-world applications.
Mihaela Grib   +6 more
doaj   +1 more source

Evaluation of Lithium-Ion Battery Equivalent Circuit Models for State of Charge Estimation by an Experimental Approach

open access: yesEnergies, 2011
To improve the use of lithium-ion batteries in electric vehicle (EV) applications, evaluations and comparisons of different equivalent circuit models are presented in this paper.
Jinxin Fan, Hongwen He, Rui Xiong
doaj   +1 more source

Voltage harmonic reduction for randomly time-varying source characteristics and voltage harmonics [PDF]

open access: yes, 2006
This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Brunel University's products or services. Internal or personal use of this material is permitted.
Zobaa, AF
core   +1 more source

Stability and Synchronization of MMC‐HVDC Systems Using SRF and Inertia‐Based PLLs

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
This study investigates the influence of synchronous reference frame PLL (SRF‐PLL) and the inertia PLL (IPLL) on the stability of grid‐connected modular multilevel converter high voltage direct current (MMC‐HVDC) systems. The findings highlight intrinsic stability limitations of PLL‐based systems, offering insights toward more stable, PLL‐less ...
Shuai Wang, Robin Preece, Mike Barnes
wiley   +1 more source

Dead-time effect modeling for hybrid modular multilevel converter using twin mapping

open access: yesInternational Journal of Electrical Power & Energy Systems
Dead-time control is essential for modular multilevel converters (MMCs), but it negatively impacts MMC performance. To support the development of control strategies to mitigate the adverse effects of dead-time, electromagnetic transient (EMT) simulations
Moke Feng   +5 more
doaj   +1 more source

A Novel Bi-LSTM-Based Method for Thevenin Equivalent Parameter Identification

open access: yesFrontiers in Energy Research, 2022
Insufficient power system operation data sets hinder the extensive application of various artificial intelligence algorithms. The solution of the Thevenin equivalent parameters especially depends on the power flow data of the grid.
Chengyu Li, Jilai Yu, Jiaxin Lv
doaj   +1 more source

Analysis of a Three Phase Induction Motor Directly from Maxwell's Equations

open access: yes, 2011
The torque developed in a three phase AC squirrel cage motor is usually expressed in terms of resistances and reactances of the stator, the rotor, and the motor as a whole. We use Maxwell's equations to find the torque in terms of geometrical parameters.
Griffiths D. J., Shayak Bhattacharjee
core   +1 more source

Total Distortion—A New Power Quality Index on Current Harmonic Evaluation for Users With Internal Loads and DERs

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
ABSTRACT The IEEE Std 519–2022 IEEE Standard for harmonic control in electric power systems is widely used for controlling the harmonics in the electric power system. It uses the total demand distortion (TDD) for current harmonic evaluation at the point of common coupling (PCC).
Sivaraman P   +3 more
wiley   +1 more source

A New Procedure Based on Continuous RTU Measurement to Estimate Multi-port Thevenin Equivalent Circuit Parameters of an External Power System [PDF]

open access: yesIranian Journal of Electrical and Electronic Engineering
In this paper, a novel method is presented that can accurately estimate the Thevenin equivalent circuit parameters of an external power system by RTUs. The presented method is based on the simultaneous measurements of the desired points in the boundary ...
Nabiollah Ramezani   +1 more
doaj  

Home - About - Disclaimer - Privacy